Summary: |
Broadband ferromagnetic resonance (bbFMR) spectroscopy is an established experimental tool to quantify magnetic properties. Due to frequency-dependent transmission of the microwave setup, bbFMR measurements in the frequency domain require a suitable background removal method. Here, we present a measurement and data analysis protocol that allows us to perform quantitative frequency-swept bbFMR measurements without the need for a calibration of the microwave setup. We furthermore compare the results of the proposed frequency space analysis and a conventional analysis in field-space of bbFMR data obtained from a permalloy thin film. The very good agreement of the extracted parameters using the two methods shows the reliability of our method.
|
Subject (DDC): | 530 Physics |
Refereed: | Yes |
Files | Size | Format | View |
---|---|---|---|
There are no files associated with this item. |
MAIER-FLAIG, Hannes, Sebastian T. B. GÖNNENWEIN, Ryo OHSHIMA, Masashi SHIRAISHI, Rudolf GROSS, Hans HUEBL, Mathias WEILER, 2018. Note: Derivative divide, a method for the analysis of broadband ferromagnetic resonance in the frequency domain. In: Review of Scientific Instruments. American Institute of Physics (AIP). 89(7), 076101. ISSN 0034-6748. eISSN 1089-7623. Available under: doi: 10.1063/1.5045135
@article{MaierFlaig2018-07Deriv-52287, title={Note: Derivative divide, a method for the analysis of broadband ferromagnetic resonance in the frequency domain}, year={2018}, doi={10.1063/1.5045135}, number={7}, volume={89}, issn={0034-6748}, journal={Review of Scientific Instruments}, author={Maier-Flaig, Hannes and Gönnenwein, Sebastian T. B. and Ohshima, Ryo and Shiraishi, Masashi and Gross, Rudolf and Huebl, Hans and Weiler, Mathias}, note={Article Number: 076101} }
<rdf:RDF xmlns:dcterms="http://purl.org/dc/terms/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:bibo="http://purl.org/ontology/bibo/" xmlns:dspace="http://digital-repositories.org/ontologies/dspace/0.1.0#" xmlns:foaf="http://xmlns.com/foaf/0.1/" xmlns:void="http://rdfs.org/ns/void#" xmlns:xsd="http://www.w3.org/2001/XMLSchema#" > <rdf:Description rdf:about="https://kops.uni-konstanz.de/rdf/resource/123456789/52287"> <dc:contributor>Weiler, Mathias</dc:contributor> <dc:contributor>Gönnenwein, Sebastian T. B.</dc:contributor> <dcterms:issued>2018-07</dcterms:issued> <bibo:uri rdf:resource="https://kops.uni-konstanz.de/handle/123456789/52287"/> <dc:contributor>Ohshima, Ryo</dc:contributor> <dc:contributor>Shiraishi, Masashi</dc:contributor> <dc:creator>Gönnenwein, Sebastian T. B.</dc:creator> <dc:creator>Gross, Rudolf</dc:creator> <dcterms:title>Note: Derivative divide, a method for the analysis of broadband ferromagnetic resonance in the frequency domain</dcterms:title> <dc:contributor>Maier-Flaig, Hannes</dc:contributor> <dcterms:abstract xml:lang="eng">Broadband ferromagnetic resonance (bbFMR) spectroscopy is an established experimental tool to quantify magnetic properties. Due to frequency-dependent transmission of the microwave setup, bbFMR measurements in the frequency domain require a suitable background removal method. Here, we present a measurement and data analysis protocol that allows us to perform quantitative frequency-swept bbFMR measurements without the need for a calibration of the microwave setup. We furthermore compare the results of the proposed frequency space analysis and a conventional analysis in field-space of bbFMR data obtained from a permalloy thin film. The very good agreement of the extracted parameters using the two methods shows the reliability of our method.</dcterms:abstract> <void:sparqlEndpoint rdf:resource="http://localhost/fuseki/dspace/sparql"/> <dc:rights>terms-of-use</dc:rights> <dcterms:isPartOf rdf:resource="https://kops.uni-konstanz.de/rdf/resource/123456789/41"/> <dspace:isPartOfCollection rdf:resource="https://kops.uni-konstanz.de/rdf/resource/123456789/41"/> <dc:creator>Maier-Flaig, Hannes</dc:creator> <dc:creator>Ohshima, Ryo</dc:creator> <dc:contributor>Huebl, Hans</dc:contributor> <dc:date rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2021-01-05T10:46:22Z</dc:date> <dcterms:rights rdf:resource="https://rightsstatements.org/page/InC/1.0/"/> <dc:language>eng</dc:language> <dcterms:available rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2021-01-05T10:46:22Z</dcterms:available> <foaf:homepage rdf:resource="http://localhost:8080/jspui"/> <dc:creator>Shiraishi, Masashi</dc:creator> <dc:creator>Weiler, Mathias</dc:creator> <dc:contributor>Gross, Rudolf</dc:contributor> <dc:creator>Huebl, Hans</dc:creator> </rdf:Description> </rdf:RDF>