Magnon detection using a ferroic collinear multilayer spin valve

Zitieren

Dateien zu dieser Ressource

Prüfsumme: MD5:1681b501a4866c01720ab507509c6184

CRAMER, Joel, Felix FUHRMANN, Ulrike RITZMANN, Vanessa GALL, Tomohiko NIIZEKI, Rafael RAMOS, Zhiyong QIU, Dazhi HOU, Ulrich NOWAK, Mathias KLÄUI, 2018. Magnon detection using a ferroic collinear multilayer spin valve. In: Nature communications. 9(1), 1089. eISSN 2041-1723. Available under: doi: 10.1038/s41467-018-03485-5

@article{Cramer2018-03-14Magno-42143, title={Magnon detection using a ferroic collinear multilayer spin valve}, year={2018}, doi={10.1038/s41467-018-03485-5}, number={1}, volume={9}, journal={Nature communications}, author={Cramer, Joel and Fuhrmann, Felix and Ritzmann, Ulrike and Gall, Vanessa and Niizeki, Tomohiko and Ramos, Rafael and Qiu, Zhiyong and Hou, Dazhi and Nowak, Ulrich and Kläui, Mathias}, note={Article Number: 1089} }

Ritzmann, Ulrike Kläui, Mathias Ramos, Rafael 2018-04-23T14:28:05Z eng Information transport and processing by pure magnonic spin currents in insulators is a promising alternative to conventional charge-current-driven spintronic devices. The absence of Joule heating and reduced spin wave damping in insulating ferromagnets have been suggested for implementing efficient logic devices. After the successful demonstration of a majority gate based on the superposition of spin waves, further components are required to perform complex logic operations. Here, we report on magnetization orientation-dependent spin current detection signals in collinear magnetic multilayers inspired by the functionality of a conventional spin valve. In Y<sub>3</sub>Fe<sub>5</sub>O<sub>12</sub>|CoO|Co, we find that the detection amplitude of spin currents emitted by ferromagnetic resonance spin pumping depends on the relative alignment of the Y<sub>3</sub>Fe<sub>5</sub>O<sub>12</sub>and Co magnetization. This yields a spin valve-like behavior with an amplitude change of 120% in our systems. We demonstrate the reliability of the effect and identify its origin by both temperature-dependent and power-dependent measurements. Gall, Vanessa Niizeki, Tomohiko Niizeki, Tomohiko Nowak, Ulrich Fuhrmann, Felix Qiu, Zhiyong Ritzmann, Ulrike 2018-03-14 Hou, Dazhi Qiu, Zhiyong Magnon detection using a ferroic collinear multilayer spin valve Hou, Dazhi Cramer, Joel Fuhrmann, Felix 2018-04-23T14:28:05Z Cramer, Joel Nowak, Ulrich terms-of-use Ramos, Rafael Kläui, Mathias Gall, Vanessa

Dateiabrufe seit 23.04.2018 (Informationen über die Zugriffsstatistik)

Cramer_2-u87jys2kop2k0.pdf 8

Das Dokument erscheint in:

KOPS Suche


Stöbern

Mein Benutzerkonto