Analysis of Draize eye irritation testing and its prediction by mining publicly available 2008-2014 REACH data
Analysis of Draize eye irritation testing and its prediction by mining publicly available 2008-2014 REACH data
Date
2016
Authors
Editors
Journal ISSN
Electronic ISSN
ISBN
Bibliographical data
Publisher
Series
URI (citable link)
DOI (citable link)
International patent number
Link to the license
EU project number
681002
Project
EUToxRisk21
Open Access publication
Collections
Title in another language
Publication type
Journal article
Publication status
Published
Published in
Alternatives to Animal Experimentation : ALTEX ; 33 (2016), 2. - pp. 123-134. - ISSN 0946-7785. - eISSN 1868-8551
Abstract
Public data from ECHA online dossiers on 9,801 substances encompassing 326,749 experimental key studies and additional information on classification and labeling were made computable. Eye irritation hazard, for which the rabbit Draize eye test still represents the reference method, was analyzed. Dossiers contained 9,782 Draize eye studies on 3,420 unique substances, indicating frequent retesting of substances. This allowed assessment of the test's reproducibility test based on all substances tested more than once. There was a 10% chance of a non-irritant evaluation given after a prior severe-irritant result as given by UN GHS classification criteria. The most reproducible outcomes were the results negative (94% reproducible) and severe eye irritant (73% reproducible). To evaluate whether other GHS categorizations predict eye irritation we built a dataset of 5,629 substances (1,931 'irritant' and 3,698 'non-irritant'). The two best decision trees with up to three other GHS classifications resulted in balanced accuracies of 68% and 73%, i.e., in the rank order of the Draize rabbit eye test itself, but both use inhalation toxicity data ("May cause respiratory irritation"), which is not typically available. Next, a dataset of 929 substances with at least one Draize study was mapped to PubChem to compute chemical similarity using 2D conformational fingerprints and Tanimoto similarity. Using a minimum similarity of 0.7 and simple classification by the closest chemical neighbor resulted in balanced accuracy from 73% over 737 substances to 100% at a threshold of 0.975 over 41 substances. This represents a strong support of read-across and (Q)SAR approaches in this area.
Summary in another language
Subject (DDC)
570 Biosciences, Biology
Keywords
Conference
Review
undefined / . - undefined, undefined. - (undefined; undefined)
Cite This
ISO 690
LUECHTEFELD, Thomas, Alexandra MAERTENS, Daniel P. RUSSO, Costanza ROVIDA, Hao ZHU, Thomas HARTUNG, 2016. Analysis of Draize eye irritation testing and its prediction by mining publicly available 2008-2014 REACH data. In: Alternatives to Animal Experimentation : ALTEX. 33(2), pp. 123-134. ISSN 0946-7785. eISSN 1868-8551. Available under: doi: 10.14573/altex.1510053BibTex
@article{Luechtefeld2016Analy-35554, year={2016}, doi={10.14573/altex.1510053}, title={Analysis of Draize eye irritation testing and its prediction by mining publicly available 2008-2014 REACH data}, number={2}, volume={33}, issn={0946-7785}, journal={Alternatives to Animal Experimentation : ALTEX}, pages={123--134}, author={Luechtefeld, Thomas and Maertens, Alexandra and Russo, Daniel P. and Rovida, Costanza and Zhu, Hao and Hartung, Thomas} }
RDF
<rdf:RDF xmlns:dcterms="http://purl.org/dc/terms/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:bibo="http://purl.org/ontology/bibo/" xmlns:dspace="http://digital-repositories.org/ontologies/dspace/0.1.0#" xmlns:foaf="http://xmlns.com/foaf/0.1/" xmlns:void="http://rdfs.org/ns/void#" xmlns:xsd="http://www.w3.org/2001/XMLSchema#" > <rdf:Description rdf:about="https://kops.uni-konstanz.de/server/rdf/resource/123456789/35554"> <dspace:hasBitstream rdf:resource="https://kops.uni-konstanz.de/bitstream/123456789/35554/3/Luechtefeld_0-365916.pdf"/> <bibo:uri rdf:resource="https://kops.uni-konstanz.de/handle/123456789/35554"/> <dc:contributor>Rovida, Costanza</dc:contributor> <dcterms:abstract xml:lang="eng">Public data from ECHA online dossiers on 9,801 substances encompassing 326,749 experimental key studies and additional information on classification and labeling were made computable. Eye irritation hazard, for which the rabbit Draize eye test still represents the reference method, was analyzed. Dossiers contained 9,782 Draize eye studies on 3,420 unique substances, indicating frequent retesting of substances. This allowed assessment of the test's reproducibility test based on all substances tested more than once. There was a 10% chance of a non-irritant evaluation given after a prior severe-irritant result as given by UN GHS classification criteria. The most reproducible outcomes were the results negative (94% reproducible) and severe eye irritant (73% reproducible). To evaluate whether other GHS categorizations predict eye irritation we built a dataset of 5,629 substances (1,931 'irritant' and 3,698 'non-irritant'). The two best decision trees with up to three other GHS classifications resulted in balanced accuracies of 68% and 73%, i.e., in the rank order of the Draize rabbit eye test itself, but both use inhalation toxicity data ("May cause respiratory irritation"), which is not typically available. Next, a dataset of 929 substances with at least one Draize study was mapped to PubChem to compute chemical similarity using 2D conformational fingerprints and Tanimoto similarity. Using a minimum similarity of 0.7 and simple classification by the closest chemical neighbor resulted in balanced accuracy from 73% over 737 substances to 100% at a threshold of 0.975 over 41 substances. This represents a strong support of read-across and (Q)SAR approaches in this area.</dcterms:abstract> <dc:creator>Luechtefeld, Thomas</dc:creator> <dc:contributor>Luechtefeld, Thomas</dc:contributor> <dc:language>eng</dc:language> <dc:creator>Maertens, Alexandra</dc:creator> <dcterms:hasPart rdf:resource="https://kops.uni-konstanz.de/bitstream/123456789/35554/3/Luechtefeld_0-365916.pdf"/> <dcterms:isPartOf rdf:resource="https://kops.uni-konstanz.de/server/rdf/resource/123456789/28"/> <dc:creator>Zhu, Hao</dc:creator> <dcterms:title>Analysis of Draize eye irritation testing and its prediction by mining publicly available 2008-2014 REACH data</dcterms:title> <dc:contributor>Maertens, Alexandra</dc:contributor> <dc:contributor>Hartung, Thomas</dc:contributor> <dc:creator>Rovida, Costanza</dc:creator> <void:sparqlEndpoint rdf:resource="http://localhost/fuseki/dspace/sparql"/> <dc:creator>Russo, Daniel P.</dc:creator> <dc:creator>Hartung, Thomas</dc:creator> <dc:date rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2016-10-13T09:04:09Z</dc:date> <dcterms:rights rdf:resource="http://creativecommons.org/licenses/by/4.0/"/> <dc:contributor>Zhu, Hao</dc:contributor> <dcterms:issued>2016</dcterms:issued> <dcterms:available rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2016-10-13T09:04:09Z</dcterms:available> <dc:rights>Attribution 4.0 International</dc:rights> <foaf:homepage rdf:resource="http://localhost:8080/"/> <dc:contributor>Russo, Daniel P.</dc:contributor> <dspace:isPartOfCollection rdf:resource="https://kops.uni-konstanz.de/server/rdf/resource/123456789/28"/> </rdf:Description> </rdf:RDF>
Internal note
xmlui.Submission.submit.DescribeStep.inputForms.label.kops_note_fromSubmitter
Examination date of dissertation
Method of financing
Comment on publication
Alliance license
Corresponding Authors der Uni Konstanz vorhanden
International Co-Authors
Bibliography of Konstanz
Yes