Publikation: Development of a reliable method to assess footwear comfort during running
Dateien
Datum
Autor:innen
Herausgeber:innen
ISSN der Zeitschrift
Electronic ISSN
ISBN
Bibliografische Daten
Verlag
Schriftenreihe
Auflagebezeichnung
URI (zitierfähiger Link)
DOI (zitierfähiger Link)
Internationale Patentnummer
Angaben zur Forschungsförderung
Projekt
Open Access-Veröffentlichung
Sammlungen
Core Facility der Universität Konstanz
Titel in einer weiteren Sprache
Publikationstyp
Publikationsstatus
Erschienen in
Zusammenfassung
The purposes of this study were: (a) to determine whether subjects are able to distinguish between differences in footwear with respect to footwear comfort; and (b) to determine how reliably footwear comfort can be assessed using a visual analogue scale (VAS) and a protocol including a control condition during running. Intraclass correlation coefficients (ICCs) between comfort ratings for repeated conditions were high (ICC = 0.799). Differences in comfort ratings between the insert conditions were significant. A paired t-test revealed a significant difference in overall comfort ratings for the control insert when tested after the soft insert compared to when tested after the hard insert (P = 0.008). The results of this study showed that VASs provide a reliable measure to assess footwear comfort during running under the conditions that: (a) a control condition is included; and (b) the average comfort rating of sessions 4-6 is used.
Zusammenfassung in einer weiteren Sprache
Fachgebiet (DDC)
Schlagwörter
Konferenz
Rezension
Zitieren
ISO 690
MÜNDERMANN, Annegret, Benno M. NIGG, Darren J. STEFANYSHYN, R. Neil HUMBLE, 2002. Development of a reliable method to assess footwear comfort during running. In: Gait & Posture. 2002, 16(1), pp. 38-45. ISSN 0966-6362. Available under: doi: 10.1016/S0966-6362(01)00197-7BibTex
@article{Mundermann2002Devel-17902,
year={2002},
doi={10.1016/S0966-6362(01)00197-7},
title={Development of a reliable method to assess footwear comfort during running},
number={1},
volume={16},
issn={0966-6362},
journal={Gait & Posture},
pages={38--45},
author={Mündermann, Annegret and Nigg, Benno M. and Stefanyshyn, Darren J. and Humble, R. Neil}
}RDF
<rdf:RDF
xmlns:dcterms="http://purl.org/dc/terms/"
xmlns:dc="http://purl.org/dc/elements/1.1/"
xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#"
xmlns:bibo="http://purl.org/ontology/bibo/"
xmlns:dspace="http://digital-repositories.org/ontologies/dspace/0.1.0#"
xmlns:foaf="http://xmlns.com/foaf/0.1/"
xmlns:void="http://rdfs.org/ns/void#"
xmlns:xsd="http://www.w3.org/2001/XMLSchema#" >
<rdf:Description rdf:about="https://kops.uni-konstanz.de/server/rdf/resource/123456789/17902">
<dc:contributor>Humble, R. Neil</dc:contributor>
<foaf:homepage rdf:resource="http://localhost:8080/"/>
<dcterms:title>Development of a reliable method to assess footwear comfort during running</dcterms:title>
<dcterms:isPartOf rdf:resource="https://kops.uni-konstanz.de/server/rdf/resource/123456789/35"/>
<dcterms:bibliographicCitation>Publ. in: Gait & Posture ; 16 (2002), 1. - S. 38-45</dcterms:bibliographicCitation>
<dc:rights>terms-of-use</dc:rights>
<dc:contributor>Stefanyshyn, Darren J.</dc:contributor>
<dcterms:available rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2012-02-06T09:41:02Z</dcterms:available>
<void:sparqlEndpoint rdf:resource="http://localhost/fuseki/dspace/sparql"/>
<dcterms:abstract xml:lang="eng">The purposes of this study were: (a) to determine whether subjects are able to distinguish between differences in footwear with respect to footwear comfort; and (b) to determine how reliably footwear comfort can be assessed using a visual analogue scale (VAS) and a protocol including a control condition during running. Intraclass correlation coefficients (ICCs) between comfort ratings for repeated conditions were high (ICC = 0.799). Differences in comfort ratings between the insert conditions were significant. A paired t-test revealed a significant difference in overall comfort ratings for the control insert when tested after the soft insert compared to when tested after the hard insert (P = 0.008). The results of this study showed that VASs provide a reliable measure to assess footwear comfort during running under the conditions that: (a) a control condition is included; and (b) the average comfort rating of sessions 4-6 is used.</dcterms:abstract>
<dc:creator>Mündermann, Annegret</dc:creator>
<dc:language>eng</dc:language>
<dc:date rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2012-02-06T09:41:02Z</dc:date>
<dcterms:issued>2002</dcterms:issued>
<dc:creator>Nigg, Benno M.</dc:creator>
<dcterms:rights rdf:resource="https://rightsstatements.org/page/InC/1.0/"/>
<dc:creator>Stefanyshyn, Darren J.</dc:creator>
<dspace:isPartOfCollection rdf:resource="https://kops.uni-konstanz.de/server/rdf/resource/123456789/35"/>
<dc:contributor>Mündermann, Annegret</dc:contributor>
<dc:creator>Humble, R. Neil</dc:creator>
<dc:contributor>Nigg, Benno M.</dc:contributor>
<bibo:uri rdf:resource="http://kops.uni-konstanz.de/handle/123456789/17902"/>
</rdf:Description>
</rdf:RDF>