Publikation: Development of a reliable method to assess footwear comfort during running
Dateien
Datum
Autor:innen
Herausgeber:innen
ISSN der Zeitschrift
Electronic ISSN
ISBN
Bibliografische Daten
Verlag
Schriftenreihe
Auflagebezeichnung
URI (zitierfähiger Link)
DOI (zitierfähiger Link)
Internationale Patentnummer
Angaben zur Forschungsförderung
Projekt
Open Access-Veröffentlichung
Sammlungen
Core Facility der Universität Konstanz
Titel in einer weiteren Sprache
Publikationstyp
Publikationsstatus
Erschienen in
Zusammenfassung
The purposes of this study were: (a) to determine whether subjects are able to distinguish between differences in footwear with respect to footwear comfort; and (b) to determine how reliably footwear comfort can be assessed using a visual analogue scale (VAS) and a protocol including a control condition during running. Intraclass correlation coefficients (ICCs) between comfort ratings for repeated conditions were high (ICC = 0.799). Differences in comfort ratings between the insert conditions were significant. A paired t-test revealed a significant difference in overall comfort ratings for the control insert when tested after the soft insert compared to when tested after the hard insert (P = 0.008). The results of this study showed that VASs provide a reliable measure to assess footwear comfort during running under the conditions that: (a) a control condition is included; and (b) the average comfort rating of sessions 4-6 is used.
Zusammenfassung in einer weiteren Sprache
Fachgebiet (DDC)
Schlagwörter
Konferenz
Rezension
Zitieren
ISO 690
MÜNDERMANN, Annegret, Benno M. NIGG, Darren J. STEFANYSHYN, R. Neil HUMBLE, 2002. Development of a reliable method to assess footwear comfort during running. In: Gait & Posture. 2002, 16(1), pp. 38-45. ISSN 0966-6362. Available under: doi: 10.1016/S0966-6362(01)00197-7BibTex
@article{Mundermann2002Devel-17902, year={2002}, doi={10.1016/S0966-6362(01)00197-7}, title={Development of a reliable method to assess footwear comfort during running}, number={1}, volume={16}, issn={0966-6362}, journal={Gait & Posture}, pages={38--45}, author={Mündermann, Annegret and Nigg, Benno M. and Stefanyshyn, Darren J. and Humble, R. Neil} }
RDF
<rdf:RDF xmlns:dcterms="http://purl.org/dc/terms/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:bibo="http://purl.org/ontology/bibo/" xmlns:dspace="http://digital-repositories.org/ontologies/dspace/0.1.0#" xmlns:foaf="http://xmlns.com/foaf/0.1/" xmlns:void="http://rdfs.org/ns/void#" xmlns:xsd="http://www.w3.org/2001/XMLSchema#" > <rdf:Description rdf:about="https://kops.uni-konstanz.de/server/rdf/resource/123456789/17902"> <dc:contributor>Humble, R. Neil</dc:contributor> <foaf:homepage rdf:resource="http://localhost:8080/"/> <dcterms:title>Development of a reliable method to assess footwear comfort during running</dcterms:title> <dcterms:isPartOf rdf:resource="https://kops.uni-konstanz.de/server/rdf/resource/123456789/35"/> <dcterms:bibliographicCitation>Publ. in: Gait & Posture ; 16 (2002), 1. - S. 38-45</dcterms:bibliographicCitation> <dc:rights>terms-of-use</dc:rights> <dc:contributor>Stefanyshyn, Darren J.</dc:contributor> <dcterms:available rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2012-02-06T09:41:02Z</dcterms:available> <void:sparqlEndpoint rdf:resource="http://localhost/fuseki/dspace/sparql"/> <dcterms:abstract xml:lang="eng">The purposes of this study were: (a) to determine whether subjects are able to distinguish between differences in footwear with respect to footwear comfort; and (b) to determine how reliably footwear comfort can be assessed using a visual analogue scale (VAS) and a protocol including a control condition during running. Intraclass correlation coefficients (ICCs) between comfort ratings for repeated conditions were high (ICC = 0.799). Differences in comfort ratings between the insert conditions were significant. A paired t-test revealed a significant difference in overall comfort ratings for the control insert when tested after the soft insert compared to when tested after the hard insert (P = 0.008). The results of this study showed that VASs provide a reliable measure to assess footwear comfort during running under the conditions that: (a) a control condition is included; and (b) the average comfort rating of sessions 4-6 is used.</dcterms:abstract> <dc:creator>Mündermann, Annegret</dc:creator> <dc:language>eng</dc:language> <dc:date rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2012-02-06T09:41:02Z</dc:date> <dcterms:issued>2002</dcterms:issued> <dc:creator>Nigg, Benno M.</dc:creator> <dcterms:rights rdf:resource="https://rightsstatements.org/page/InC/1.0/"/> <dc:creator>Stefanyshyn, Darren J.</dc:creator> <dspace:isPartOfCollection rdf:resource="https://kops.uni-konstanz.de/server/rdf/resource/123456789/35"/> <dc:contributor>Mündermann, Annegret</dc:contributor> <dc:creator>Humble, R. Neil</dc:creator> <dc:contributor>Nigg, Benno M.</dc:contributor> <bibo:uri rdf:resource="http://kops.uni-konstanz.de/handle/123456789/17902"/> </rdf:Description> </rdf:RDF>