Fluorescence-Lifetime-Sensitive Probes for Monitoring ATP Cleavage
| dc.contributor.author | Hammler, Daniel | |
| dc.contributor.author | Marx, Andreas | |
| dc.contributor.author | Zumbusch, Andreas | |
| dc.date.accessioned | 2018-09-22T10:06:51Z | |
| dc.date.available | 2018-09-22T10:06:51Z | |
| dc.date.issued | 2018-10-12 | |
| dc.description.abstract | Adenosine triphosphate (ATP) probes modified with fluorescence dyes that change their fluorescence properties upon cleavage are an interesting tool for monitoring enzymatic ATP turnover. As a readout parameter, fluorescence lifetime is attractive because it is nearly independent of concentration. In our study, we synthesised and investigated fifteen different ATP analogues, in which the fluorophores were attached to the γ-phosphate of ATP. All analogues showed distinctly different fluorescence lifetimes compared to the corresponding values of the free fluorophores. Both increases and decreases in fluorescence lifetime were observed upon attachment to ATP. To shed light on the photophysical processes governing the lifetime changes, we performed photoelectron spectroscopy in air (PESA) to determine HOMO energy levels and time-resolved fluorescence spectroscopy to obtain rate constants. We present evidence that fluorescence quenching in the compounds tested is dynamic and attributed to photoinduced electron transfer (PET), whereas fluorescence lifetime increases are caused by stacking interactions between chromophore and the nucleobase reducing non-radiative relaxation. Finally, we demonstrate that enzymatic cleavage of the ATP analogues presented can be followed by continuous monitoring of fluorescence lifetime changes. | eng |
| dc.description.version | published | eng |
| dc.identifier.doi | 10.1002/chem.201803234 | eng |
| dc.identifier.pmid | 30070405 | eng |
| dc.identifier.ppn | 1843634147 | |
| dc.identifier.uri | https://kops.uni-konstanz.de/handle/123456789/43368 | |
| dc.language.iso | eng | eng |
| dc.subject.ddc | 540 | eng |
| dc.title | Fluorescence-Lifetime-Sensitive Probes for Monitoring ATP Cleavage | eng |
| dc.type | JOURNAL_ARTICLE | eng |
| dspace.entity.type | Publication | |
| kops.citation.bibtex | @article{Hammler2018-10-12Fluor-43368,
year={2018},
doi={10.1002/chem.201803234},
title={Fluorescence-Lifetime-Sensitive Probes for Monitoring ATP Cleavage},
number={57},
volume={24},
issn={0947-6539},
journal={Chemistry : A European Journal},
pages={15329--15335},
author={Hammler, Daniel and Marx, Andreas and Zumbusch, Andreas}
} | |
| kops.citation.iso690 | HAMMLER, Daniel, Andreas MARX, Andreas ZUMBUSCH, 2018. Fluorescence-Lifetime-Sensitive Probes for Monitoring ATP Cleavage. In: Chemistry : A European Journal. 2018, 24(57), pp. 15329-15335. ISSN 0947-6539. eISSN 1521-3765. Available under: doi: 10.1002/chem.201803234 | deu |
| kops.citation.iso690 | HAMMLER, Daniel, Andreas MARX, Andreas ZUMBUSCH, 2018. Fluorescence-Lifetime-Sensitive Probes for Monitoring ATP Cleavage. In: Chemistry : A European Journal. 2018, 24(57), pp. 15329-15335. ISSN 0947-6539. eISSN 1521-3765. Available under: doi: 10.1002/chem.201803234 | eng |
| kops.citation.rdf | <rdf:RDF
xmlns:dcterms="http://purl.org/dc/terms/"
xmlns:dc="http://purl.org/dc/elements/1.1/"
xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#"
xmlns:bibo="http://purl.org/ontology/bibo/"
xmlns:dspace="http://digital-repositories.org/ontologies/dspace/0.1.0#"
xmlns:foaf="http://xmlns.com/foaf/0.1/"
xmlns:void="http://rdfs.org/ns/void#"
xmlns:xsd="http://www.w3.org/2001/XMLSchema#" >
<rdf:Description rdf:about="https://kops.uni-konstanz.de/server/rdf/resource/123456789/43368">
<dc:contributor>Hammler, Daniel</dc:contributor>
<dcterms:available rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2018-09-22T10:06:51Z</dcterms:available>
<dc:creator>Zumbusch, Andreas</dc:creator>
<dcterms:hasPart rdf:resource="https://kops.uni-konstanz.de/bitstream/123456789/43368/1/Hammler_2-ylr0ptevh4q49.pdf"/>
<dc:contributor>Marx, Andreas</dc:contributor>
<dc:language>eng</dc:language>
<dcterms:abstract xml:lang="eng">Adenosine triphosphate (ATP) probes modified with fluorescence dyes that change their fluorescence properties upon cleavage are an interesting tool for monitoring enzymatic ATP turnover. As a readout parameter, fluorescence lifetime is attractive because it is nearly independent of concentration. In our study, we synthesised and investigated fifteen different ATP analogues, in which the fluorophores were attached to the γ-phosphate of ATP. All analogues showed distinctly different fluorescence lifetimes compared to the corresponding values of the free fluorophores. Both increases and decreases in fluorescence lifetime were observed upon attachment to ATP. To shed light on the photophysical processes governing the lifetime changes, we performed photoelectron spectroscopy in air (PESA) to determine HOMO energy levels and time-resolved fluorescence spectroscopy to obtain rate constants. We present evidence that fluorescence quenching in the compounds tested is dynamic and attributed to photoinduced electron transfer (PET), whereas fluorescence lifetime increases are caused by stacking interactions between chromophore and the nucleobase reducing non-radiative relaxation. Finally, we demonstrate that enzymatic cleavage of the ATP analogues presented can be followed by continuous monitoring of fluorescence lifetime changes.</dcterms:abstract>
<dc:creator>Hammler, Daniel</dc:creator>
<dspace:hasBitstream rdf:resource="https://kops.uni-konstanz.de/bitstream/123456789/43368/1/Hammler_2-ylr0ptevh4q49.pdf"/>
<dspace:isPartOfCollection rdf:resource="https://kops.uni-konstanz.de/server/rdf/resource/123456789/29"/>
<dcterms:issued>2018-10-12</dcterms:issued>
<void:sparqlEndpoint rdf:resource="http://localhost/fuseki/dspace/sparql"/>
<foaf:homepage rdf:resource="http://localhost:8080/"/>
<dc:creator>Marx, Andreas</dc:creator>
<dcterms:isPartOf rdf:resource="https://kops.uni-konstanz.de/server/rdf/resource/123456789/29"/>
<bibo:uri rdf:resource="https://kops.uni-konstanz.de/handle/123456789/43368"/>
<dcterms:title>Fluorescence-Lifetime-Sensitive Probes for Monitoring ATP Cleavage</dcterms:title>
<dc:contributor>Zumbusch, Andreas</dc:contributor>
<dc:date rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2018-09-22T10:06:51Z</dc:date>
</rdf:Description>
</rdf:RDF> | |
| kops.description.openAccess | openaccessgreen | |
| kops.flag.isPeerReviewed | true | eng |
| kops.flag.knbibliography | true | |
| kops.identifier.nbn | urn:nbn:de:bsz:352-2-ylr0ptevh4q49 | |
| kops.sourcefield | Chemistry : A European Journal. 2018, <b>24</b>(57), pp. 15329-15335. ISSN 0947-6539. eISSN 1521-3765. Available under: doi: 10.1002/chem.201803234 | deu |
| kops.sourcefield.plain | Chemistry : A European Journal. 2018, 24(57), pp. 15329-15335. ISSN 0947-6539. eISSN 1521-3765. Available under: doi: 10.1002/chem.201803234 | deu |
| kops.sourcefield.plain | Chemistry : A European Journal. 2018, 24(57), pp. 15329-15335. ISSN 0947-6539. eISSN 1521-3765. Available under: doi: 10.1002/chem.201803234 | eng |
| relation.isAuthorOfPublication | cbea9a71-fcfd-4af0-900f-3ddca28d7f68 | |
| relation.isAuthorOfPublication | 3488d192-4e21-4a69-8956-f7d02d9f9b3a | |
| relation.isAuthorOfPublication | 8a4ebc3e-e511-427c-9508-17f903aa2351 | |
| relation.isAuthorOfPublication.latestForDiscovery | cbea9a71-fcfd-4af0-900f-3ddca28d7f68 | |
| source.bibliographicInfo.fromPage | 15329 | |
| source.bibliographicInfo.issue | 57 | |
| source.bibliographicInfo.toPage | 15335 | |
| source.bibliographicInfo.volume | 24 | |
| source.identifier.eissn | 1521-3765 | eng |
| source.identifier.issn | 0947-6539 | eng |
| source.periodicalTitle | Chemistry : A European Journal | eng |
Dateien
Originalbündel
1 - 1 von 1
Vorschaubild nicht verfügbar
- Name:
- Hammler_2-ylr0ptevh4q49.pdf
- Größe:
- 987.59 KB
- Format:
- Adobe Portable Document Format