Practical Aspects of Multiwavelength Analytical Ultracentrifugation

dc.contributor.authorPearson, Joseph
dc.contributor.authorCölfen, Helmut
dc.date.accessioned2019-05-09T08:11:33Z
dc.date.available2019-05-09T08:11:33Z
dc.date.issued2019-03-21eng
dc.description.abstractOpen-source Multiwavelength Analytical Ultracentrifugation (MWL-AUC) detection systems have been evolving for over a decade. Continual advances emerging out of several research groups have brought the instrumentation technology to increasingly higher levels of performance. The capabilities of MWL-AUC have been documented in many publications, demonstrating the applicability of broad spectrum absorbance acquisitions in analytical ultracentrifugation to a wide array of scientific fields. Despite numerous examples of the usefulness and unique advantages of MWL-AUC, the adoption of the technology by more research groups has been slow. The complexity of the hardware, integration within an ultracentrifuge platform and lack of practical construction and operational information is the likely source of reluctance. Here, we clearly describe the challenges facing a researcher considering adopting MWL-AUC technology in their own laboratories, and provide the information necessary to implement and operate a MWL-AUC system. The discussion includes details of detector assembly, optical alignment, and acquisition parameter settings necessary to achieve high quality experimental results.eng
dc.description.versionpublishedeng
dc.identifier.doi10.3390/instruments3010023eng
dc.identifier.ppn1665033878
dc.identifier.urihttps://kops.uni-konstanz.de/handle/123456789/45791
dc.language.isoengeng
dc.rightsAttribution 4.0 International
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subjectanalytical ultracentrifugation; multiwavelength; Open-AUCeng
dc.subject.ddc540eng
dc.titlePractical Aspects of Multiwavelength Analytical Ultracentrifugationeng
dc.typeJOURNAL_ARTICLEeng
dspace.entity.typePublication
kops.citation.bibtex
@article{Pearson2019-03-21Pract-45791,
  year={2019},
  doi={10.3390/instruments3010023},
  title={Practical Aspects of Multiwavelength Analytical Ultracentrifugation},
  number={1},
  volume={3},
  journal={Instruments},
  author={Pearson, Joseph and Cölfen, Helmut},
  note={Article Number: 23}
}
kops.citation.iso690PEARSON, Joseph, Helmut CÖLFEN, 2019. Practical Aspects of Multiwavelength Analytical Ultracentrifugation. In: Instruments. 2019, 3(1), 23. eISSN 2410-390X. Available under: doi: 10.3390/instruments3010023deu
kops.citation.iso690PEARSON, Joseph, Helmut CÖLFEN, 2019. Practical Aspects of Multiwavelength Analytical Ultracentrifugation. In: Instruments. 2019, 3(1), 23. eISSN 2410-390X. Available under: doi: 10.3390/instruments3010023eng
kops.citation.rdf
<rdf:RDF
    xmlns:dcterms="http://purl.org/dc/terms/"
    xmlns:dc="http://purl.org/dc/elements/1.1/"
    xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#"
    xmlns:bibo="http://purl.org/ontology/bibo/"
    xmlns:dspace="http://digital-repositories.org/ontologies/dspace/0.1.0#"
    xmlns:foaf="http://xmlns.com/foaf/0.1/"
    xmlns:void="http://rdfs.org/ns/void#"
    xmlns:xsd="http://www.w3.org/2001/XMLSchema#" > 
  <rdf:Description rdf:about="https://kops.uni-konstanz.de/server/rdf/resource/123456789/45791">
    <dc:language>eng</dc:language>
    <dcterms:abstract xml:lang="eng">Open-source Multiwavelength Analytical Ultracentrifugation (MWL-AUC) detection systems have been evolving for over a decade. Continual advances emerging out of several research groups have brought the instrumentation technology to increasingly higher levels of performance. The capabilities of MWL-AUC have been documented in many publications, demonstrating the applicability of broad spectrum absorbance acquisitions in analytical ultracentrifugation to a wide array of scientific fields. Despite numerous examples of the usefulness and unique advantages of MWL-AUC, the adoption of the technology by more research groups has been slow. The complexity of the hardware, integration within an ultracentrifuge platform and lack of practical construction and operational information is the likely source of reluctance. Here, we clearly describe the challenges facing a researcher considering adopting MWL-AUC technology in their own laboratories, and provide the information necessary to implement and operate a MWL-AUC system. The discussion includes details of detector assembly, optical alignment, and acquisition parameter settings necessary to achieve high quality experimental results.</dcterms:abstract>
    <dc:creator>Pearson, Joseph</dc:creator>
    <void:sparqlEndpoint rdf:resource="http://localhost/fuseki/dspace/sparql"/>
    <dc:date rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2019-05-09T08:11:33Z</dc:date>
    <foaf:homepage rdf:resource="http://localhost:8080/"/>
    <dspace:hasBitstream rdf:resource="https://kops.uni-konstanz.de/bitstream/123456789/45791/3/Pearson_2-164d9y35qux4w3.pdf"/>
    <dc:rights>Attribution 4.0 International</dc:rights>
    <dcterms:available rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2019-05-09T08:11:33Z</dcterms:available>
    <dc:creator>Cölfen, Helmut</dc:creator>
    <dcterms:hasPart rdf:resource="https://kops.uni-konstanz.de/bitstream/123456789/45791/3/Pearson_2-164d9y35qux4w3.pdf"/>
    <dcterms:rights rdf:resource="http://creativecommons.org/licenses/by/4.0/"/>
    <dcterms:issued>2019-03-21</dcterms:issued>
    <dcterms:isPartOf rdf:resource="https://kops.uni-konstanz.de/server/rdf/resource/123456789/29"/>
    <dc:contributor>Pearson, Joseph</dc:contributor>
    <bibo:uri rdf:resource="https://kops.uni-konstanz.de/handle/123456789/45791"/>
    <dcterms:title>Practical Aspects of Multiwavelength Analytical Ultracentrifugation</dcterms:title>
    <dc:contributor>Cölfen, Helmut</dc:contributor>
    <dspace:isPartOfCollection rdf:resource="https://kops.uni-konstanz.de/server/rdf/resource/123456789/29"/>
  </rdf:Description>
</rdf:RDF>
kops.description.openAccessopenaccessgoldeng
kops.flag.isPeerReviewedunknowneng
kops.flag.knbibliographytrue
kops.identifier.nbnurn:nbn:de:bsz:352-2-164d9y35qux4w3
kops.sourcefieldInstruments. 2019, <b>3</b>(1), 23. eISSN 2410-390X. Available under: doi: 10.3390/instruments3010023deu
kops.sourcefield.plainInstruments. 2019, 3(1), 23. eISSN 2410-390X. Available under: doi: 10.3390/instruments3010023deu
kops.sourcefield.plainInstruments. 2019, 3(1), 23. eISSN 2410-390X. Available under: doi: 10.3390/instruments3010023eng
relation.isAuthorOfPublication340cbf22-6a86-49a6-b7aa-2ed6205c57be
relation.isAuthorOfPublication4bb493dd-f4c7-4ece-aab9-913000b58820
relation.isAuthorOfPublication.latestForDiscovery340cbf22-6a86-49a6-b7aa-2ed6205c57be
source.bibliographicInfo.articleNumber23eng
source.bibliographicInfo.issue1eng
source.bibliographicInfo.volume3eng
source.identifier.eissn2410-390Xeng
source.periodicalTitleInstrumentseng

Dateien

Originalbündel

Gerade angezeigt 1 - 1 von 1
Vorschaubild nicht verfügbar
Name:
Pearson_2-164d9y35qux4w3.pdf
Größe:
4.61 MB
Format:
Adobe Portable Document Format
Beschreibung:
Pearson_2-164d9y35qux4w3.pdf
Pearson_2-164d9y35qux4w3.pdfGröße: 4.61 MBDownloads: 324

Lizenzbündel

Gerade angezeigt 1 - 1 von 1
Vorschaubild nicht verfügbar
Name:
license.txt
Größe:
3.88 KB
Format:
Item-specific license agreed upon to submission
Beschreibung:
license.txt
license.txtGröße: 3.88 KBDownloads: 0