Localization of neurosurgically implanted electrodes via photograph–MRI–radiograph coregistration

dc.contributor.authorDalal, Sarang S.
dc.contributor.authorEdwards, Erikdeu
dc.contributor.authorKirsch, Heidi E.deu
dc.contributor.authorBarbaro, Nicholas M.deu
dc.contributor.authorKnight, Robert T.deu
dc.contributor.authorNagarajan, Srikantan S.deu
dc.date.accessioned2011-11-30T09:28:48Zdeu
dc.date.available2011-11-30T09:28:48Zdeu
dc.date.issued2008-09-15
dc.description.abstractIntracranial electroencephalography (iEEG) is clinically indicated for medically refractory epilepsy and is a promising approach for developing neural prosthetics. These recordings also provide valuable data for cognitive neuroscience research. Accurate localization of iEEG electrodes is essential for evaluating specific brain regions underlying the electrodes that indicate normal or pathological activity, as well as for relating research findings to neuroimaging and lesion studies. However, electrodes are frequently tucked underneath the edge of a craniotomy, inserted via a burr hole, or placed deep within the brain, where their locations cannot be verified visually or with neuronavigational systems. We show that one existing method, registration of postimplant computed tomography (CT) with preoperative magnetic resonance imaging (MRI), can result in errors exceeding 1 cm. We present a novel method for localizing iEEG electrodes using routinely acquired surgical photographs, X-ray radiographs, and magnetic resonance imaging scans. Known control points are used to compute projective transforms that link the different image sets, ultimately allowing hidden electrodes to be localized, in addition to refining the location of manually registered visible electrodes. As the technique does not require any calibration between the different image modalities, it can be applied to existing image databases. The final result is a set of electrode positions on the patient’s rendered MRI yielding locations relative to sulcal and gyral landmarks on individual anatomy, as well as MNI coordinates. We demonstrate the results of our method in eight epilepsy patients implanted with electrode grids spanning the left hemisphere.eng
dc.description.versionpublished
dc.identifier.citationPubl. in: Journal of Neuroscience Methods ; 174 (2008), 1. - S. 106-115deu
dc.identifier.doi10.1016/j.jneumeth.2008.06.028deu
dc.identifier.pmid18657573
dc.identifier.urihttp://kops.uni-konstanz.de/handle/123456789/17193
dc.language.isoengdeu
dc.legacy.dateIssued2011-11-30deu
dc.rightsterms-of-usedeu
dc.rights.urihttps://rightsstatements.org/page/InC/1.0/deu
dc.subjectSubdural electrodesdeu
dc.subjectIntracranial electroencephalographydeu
dc.subjectElectrocorticographydeu
dc.subjectEpilepsy surgerydeu
dc.subject3D localizationdeu
dc.subjectCoregistrationdeu
dc.subjectSurface renderingdeu
dc.subjectX-raydeu
dc.subjectCTdeu
dc.subjectMRIdeu
dc.subject.ddc150deu
dc.titleLocalization of neurosurgically implanted electrodes via photograph–MRI–radiograph coregistrationeng
dc.typeJOURNAL_ARTICLEdeu
dspace.entity.typePublication
kops.citation.bibtex
@article{Dalal2008-09-15Local-17193,
  year={2008},
  doi={10.1016/j.jneumeth.2008.06.028},
  title={Localization of neurosurgically implanted electrodes via photograph–MRI–radiograph coregistration},
  number={1},
  volume={174},
  issn={0165-0270},
  journal={Journal of Neuroscience Methods},
  pages={106--115},
  author={Dalal, Sarang S. and Edwards, Erik and Kirsch, Heidi E. and Barbaro, Nicholas M. and Knight, Robert T. and Nagarajan, Srikantan S.}
}
kops.citation.iso690DALAL, Sarang S., Erik EDWARDS, Heidi E. KIRSCH, Nicholas M. BARBARO, Robert T. KNIGHT, Srikantan S. NAGARAJAN, 2008. Localization of neurosurgically implanted electrodes via photograph–MRI–radiograph coregistration. In: Journal of Neuroscience Methods. 2008, 174(1), pp. 106-115. ISSN 0165-0270. Available under: doi: 10.1016/j.jneumeth.2008.06.028deu
kops.citation.iso690DALAL, Sarang S., Erik EDWARDS, Heidi E. KIRSCH, Nicholas M. BARBARO, Robert T. KNIGHT, Srikantan S. NAGARAJAN, 2008. Localization of neurosurgically implanted electrodes via photograph–MRI–radiograph coregistration. In: Journal of Neuroscience Methods. 2008, 174(1), pp. 106-115. ISSN 0165-0270. Available under: doi: 10.1016/j.jneumeth.2008.06.028eng
kops.citation.rdf
<rdf:RDF
    xmlns:dcterms="http://purl.org/dc/terms/"
    xmlns:dc="http://purl.org/dc/elements/1.1/"
    xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#"
    xmlns:bibo="http://purl.org/ontology/bibo/"
    xmlns:dspace="http://digital-repositories.org/ontologies/dspace/0.1.0#"
    xmlns:foaf="http://xmlns.com/foaf/0.1/"
    xmlns:void="http://rdfs.org/ns/void#"
    xmlns:xsd="http://www.w3.org/2001/XMLSchema#" > 
  <rdf:Description rdf:about="https://kops.uni-konstanz.de/server/rdf/resource/123456789/17193">
    <dc:creator>Dalal, Sarang S.</dc:creator>
    <dc:language>eng</dc:language>
    <dc:date rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2011-11-30T09:28:48Z</dc:date>
    <dc:creator>Edwards, Erik</dc:creator>
    <dc:contributor>Barbaro, Nicholas M.</dc:contributor>
    <dc:contributor>Knight, Robert T.</dc:contributor>
    <dc:contributor>Kirsch, Heidi E.</dc:contributor>
    <dcterms:abstract xml:lang="eng">Intracranial electroencephalography (iEEG) is clinically indicated for medically refractory epilepsy and is a promising approach for developing neural prosthetics. These recordings also provide valuable data for cognitive neuroscience research. Accurate localization of iEEG electrodes is essential for evaluating specific brain regions underlying the electrodes that indicate normal or pathological activity, as well as for relating research findings to neuroimaging and lesion studies. However, electrodes are frequently tucked underneath the edge of a craniotomy, inserted via a burr hole, or placed deep within the brain, where their locations cannot be verified visually or with neuronavigational systems. We show that one existing method, registration of postimplant computed tomography (CT) with preoperative magnetic resonance imaging (MRI), can result in errors exceeding 1 cm. We present a novel method for localizing iEEG electrodes using routinely acquired surgical photographs, X-ray radiographs, and magnetic resonance imaging scans. Known control points are used to compute projective transforms that link the different image sets, ultimately allowing hidden electrodes to be localized, in addition to refining the location of manually registered visible electrodes. As the technique does not require any calibration between the different image modalities, it can be applied to existing image databases. The final result is a set of electrode positions on the patient’s rendered MRI yielding locations relative to sulcal and gyral landmarks on individual anatomy, as well as MNI coordinates. We demonstrate the results of our method in eight epilepsy patients implanted with electrode grids spanning the left hemisphere.</dcterms:abstract>
    <dc:contributor>Nagarajan, Srikantan S.</dc:contributor>
    <bibo:uri rdf:resource="http://kops.uni-konstanz.de/handle/123456789/17193"/>
    <void:sparqlEndpoint rdf:resource="http://localhost/fuseki/dspace/sparql"/>
    <dcterms:bibliographicCitation>Publ. in: Journal of Neuroscience Methods ; 174 (2008), 1. - S. 106-115</dcterms:bibliographicCitation>
    <dspace:isPartOfCollection rdf:resource="https://kops.uni-konstanz.de/server/rdf/resource/123456789/52"/>
    <dc:contributor>Dalal, Sarang S.</dc:contributor>
    <foaf:homepage rdf:resource="http://localhost:8080/"/>
    <dc:creator>Barbaro, Nicholas M.</dc:creator>
    <dc:creator>Knight, Robert T.</dc:creator>
    <dcterms:rights rdf:resource="https://rightsstatements.org/page/InC/1.0/"/>
    <dc:rights>terms-of-use</dc:rights>
    <dspace:isPartOfCollection rdf:resource="https://kops.uni-konstanz.de/server/rdf/resource/123456789/43"/>
    <dc:creator>Nagarajan, Srikantan S.</dc:creator>
    <dc:creator>Kirsch, Heidi E.</dc:creator>
    <dcterms:available rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2011-11-30T09:28:48Z</dcterms:available>
    <dcterms:issued>2008-09-15</dcterms:issued>
    <dc:contributor>Edwards, Erik</dc:contributor>
    <dcterms:isPartOf rdf:resource="https://kops.uni-konstanz.de/server/rdf/resource/123456789/43"/>
    <dcterms:title>Localization of neurosurgically implanted electrodes via photograph–MRI–radiograph coregistration</dcterms:title>
    <dcterms:isPartOf rdf:resource="https://kops.uni-konstanz.de/server/rdf/resource/123456789/52"/>
  </rdf:Description>
</rdf:RDF>
kops.flag.knbibliographyfalse
kops.identifier.nbnurn:nbn:de:bsz:352-171936deu
kops.sourcefieldJournal of Neuroscience Methods. 2008, <b>174</b>(1), pp. 106-115. ISSN 0165-0270. Available under: doi: 10.1016/j.jneumeth.2008.06.028deu
kops.sourcefield.plainJournal of Neuroscience Methods. 2008, 174(1), pp. 106-115. ISSN 0165-0270. Available under: doi: 10.1016/j.jneumeth.2008.06.028deu
kops.sourcefield.plainJournal of Neuroscience Methods. 2008, 174(1), pp. 106-115. ISSN 0165-0270. Available under: doi: 10.1016/j.jneumeth.2008.06.028eng
kops.submitter.emailkops.ub@uni-konstanz.dedeu
relation.isAuthorOfPublication49d8fd2c-e27e-4014-af58-a0b58eaf3a9f
relation.isAuthorOfPublication.latestForDiscovery49d8fd2c-e27e-4014-af58-a0b58eaf3a9f
source.bibliographicInfo.fromPage106
source.bibliographicInfo.issue1
source.bibliographicInfo.toPage115
source.bibliographicInfo.volume174
source.identifier.issn0165-0270
source.periodicalTitleJournal of Neuroscience Methods

Dateien

Lizenzbündel

Gerade angezeigt 1 - 1 von 1
Vorschaubild nicht verfügbar
Name:
license.txt
Größe:
1.92 KB
Format:
Plain Text
Beschreibung:
license.txt
license.txtGröße: 1.92 KBDownloads: 0