Post-processing intensity measurements at favourable dose values

Lade...
Vorschaubild
Dateien
Diederichs_106461.pdf
Diederichs_106461.pdfGröße: 415.5 KBDownloads: 522
Datum
2008
Herausgeber:innen
Kontakt
ISSN der Zeitschrift
Electronic ISSN
ISBN
Bibliografische Daten
Verlag
Schriftenreihe
Auflagebezeichnung
ArXiv-ID
Internationale Patentnummer
Angaben zur Forschungsförderung
Projekt
Open Access-Veröffentlichung
Open Access Green
Sammlungen
Core Facility der Universität Konstanz
Gesperrt bis
Titel in einer weiteren Sprache
Publikationstyp
Zeitschriftenartikel
Publikationsstatus
Published
Erschienen in
Journal of Applied Crystallography. 2008, 42(1), pp. 48-57. ISSN 0021-8898. eISSN 1600-5767. Available under: doi: 10.1107/S0021889808036716
Zusammenfassung

In a macromolecular X-ray experiment, many sets of intensity measurements are collected, with each measurement corresponding to the intensity of a unique reflection at a different X-ray dose. The computational correction of radiation damage, which occurs as a function of dose during the experiment, is a concept suggesting the approximation of each set of measured intensities with a smooth function. The value of the approximating function at a user-defined point common to all unique reflections is then used as an interpolated snapshot of the true intensities at this specific dose. It is shown here that, under realistic assumptions, interpolation with a linear function has the smallest amount of error at or near two well defined points in the dose interval. This result is a special case from a mathematical analysis of polynomial approximations which proves that the points of minimum error in the approximation of a polynomial of order n by a polynomial of order n - 1 are independent of the function values. Conditions are formulated under which better intensities are obtained from linear interpolation than from the usual averaging of observations.

Zusammenfassung in einer weiteren Sprache
Fachgebiet (DDC)
510 Mathematik
Schlagwörter
favourable dose values, post-processing, intensity measurements, correction of radiation damage
Konferenz
Rezension
undefined / . - undefined, undefined
Forschungsvorhaben
Organisationseinheiten
Zeitschriftenheft
Datensätze
Zitieren
ISO 690DIEDERICHS, Kay, Michael JUNK, 2008. Post-processing intensity measurements at favourable dose values. In: Journal of Applied Crystallography. 2008, 42(1), pp. 48-57. ISSN 0021-8898. eISSN 1600-5767. Available under: doi: 10.1107/S0021889808036716
BibTex
@article{Diederichs2008Postp-762,
  year={2008},
  doi={10.1107/S0021889808036716},
  title={Post-processing intensity measurements at favourable dose values},
  number={1},
  volume={42},
  issn={0021-8898},
  journal={Journal of Applied Crystallography},
  pages={48--57},
  author={Diederichs, Kay and Junk, Michael}
}
RDF
<rdf:RDF
    xmlns:dcterms="http://purl.org/dc/terms/"
    xmlns:dc="http://purl.org/dc/elements/1.1/"
    xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#"
    xmlns:bibo="http://purl.org/ontology/bibo/"
    xmlns:dspace="http://digital-repositories.org/ontologies/dspace/0.1.0#"
    xmlns:foaf="http://xmlns.com/foaf/0.1/"
    xmlns:void="http://rdfs.org/ns/void#"
    xmlns:xsd="http://www.w3.org/2001/XMLSchema#" > 
  <rdf:Description rdf:about="https://kops.uni-konstanz.de/server/rdf/resource/123456789/762">
    <foaf:homepage rdf:resource="http://localhost:8080/"/>
    <dcterms:abstract xml:lang="eng">In a macromolecular X-ray experiment, many sets of intensity measurements are collected, with each measurement corresponding to the intensity of a unique reflection at a different X-ray dose. The computational correction of radiation damage, which occurs as a function of dose during the experiment, is a concept suggesting the approximation of each set of measured intensities with a smooth function. The value of the approximating function at a user-defined point common to all unique reflections is then used as an interpolated snapshot of the true intensities at this specific dose. It is shown here that, under realistic assumptions, interpolation with a linear function has the smallest amount of error at or near two well defined points in the dose interval. This result is a special case from a mathematical analysis of polynomial approximations which proves that the points of minimum error in the approximation of a polynomial of order n by a polynomial of order n - 1 are independent of the function values. Conditions are formulated under which better intensities are obtained from linear interpolation than from the usual averaging of observations.</dcterms:abstract>
    <void:sparqlEndpoint rdf:resource="http://localhost/fuseki/dspace/sparql"/>
    <dc:language>eng</dc:language>
    <dcterms:available rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2011-03-22T17:48:46Z</dcterms:available>
    <dspace:isPartOfCollection rdf:resource="https://kops.uni-konstanz.de/server/rdf/resource/123456789/28"/>
    <dcterms:title>Post-processing intensity measurements at favourable dose values</dcterms:title>
    <dspace:hasBitstream rdf:resource="https://kops.uni-konstanz.de/bitstream/123456789/762/1/Diederichs_106461.pdf"/>
    <dcterms:hasPart rdf:resource="https://kops.uni-konstanz.de/bitstream/123456789/762/1/Diederichs_106461.pdf"/>
    <dc:contributor>Diederichs, Kay</dc:contributor>
    <dc:contributor>Junk, Michael</dc:contributor>
    <dcterms:issued>2008</dcterms:issued>
    <dc:creator>Junk, Michael</dc:creator>
    <dcterms:isPartOf rdf:resource="https://kops.uni-konstanz.de/server/rdf/resource/123456789/28"/>
    <dcterms:rights rdf:resource="https://rightsstatements.org/page/InC/1.0/"/>
    <bibo:uri rdf:resource="http://kops.uni-konstanz.de/handle/123456789/762"/>
    <dc:creator>Diederichs, Kay</dc:creator>
    <dcterms:bibliographicCitation>Publ. in: Applied Crystallography 42 (2009), 1, pp. 48-57</dcterms:bibliographicCitation>
    <dc:rights>terms-of-use</dc:rights>
    <dc:date rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2011-03-22T17:48:46Z</dc:date>
  </rdf:Description>
</rdf:RDF>
Interner Vermerk
xmlui.Submission.submit.DescribeStep.inputForms.label.kops_note_fromSubmitter
Kontakt
URL der Originalveröffentl.
Prüfdatum der URL
Prüfungsdatum der Dissertation
Finanzierungsart
Kommentar zur Publikation
Allianzlizenz
Corresponding Authors der Uni Konstanz vorhanden
Internationale Co-Autor:innen
Universitätsbibliographie
Ja
Begutachtet
Diese Publikation teilen