KOPS - Das Institutionelle Repositorium der Universität Konstanz

Magneto-optic Investigation of Magnetic Flux Penetration on a Nanosecond Timescale

Magneto-optic Investigation of Magnetic Flux Penetration on a Nanosecond Timescale

Zitieren

Dateien zu dieser Ressource

Prüfsumme: MD5:0ed6d45fa0698a172544d5f6b339bb78

BIEHLER, Björn, Uwe BOLZ, Bernd-Uwe RUNGE, Paul LEIDERER, 2004. Magneto-optic Investigation of Magnetic Flux Penetration on a Nanosecond Timescale. In: JOHANSEN, Tom H., ed., Daniel V. SHANTSEV, ed.. Magneto-Optical Imaging. Dordrecht:Springer Netherlands, pp. 47-52. ISBN 978-1-4020-1998-2

@inproceedings{Biehler2004Magne-9088, title={Magneto-optic Investigation of Magnetic Flux Penetration on a Nanosecond Timescale}, year={2004}, doi={10.1007/978-94-007-1007-8_6}, isbn={978-1-4020-1998-2}, address={Dordrecht}, publisher={Springer Netherlands}, booktitle={Magneto-Optical Imaging}, pages={47--52}, editor={Johansen, Tom H. and Shantsev, Daniel V.}, author={Biehler, Björn and Bolz, Uwe and Runge, Bernd-Uwe and Leiderer, Paul} }

<rdf:RDF xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:bibo="http://purl.org/ontology/bibo/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:xsd="http://www.w3.org/2001/XMLSchema#" > <rdf:Description rdf:about="https://kops.uni-konstanz.de/rdf/resource/123456789/9088"> <dc:creator>Leiderer, Paul</dc:creator> <dc:creator>Runge, Bernd-Uwe</dc:creator> <dcterms:abstract xml:lang="eng">We have studied the dynamics of iron-garnet films using a pump-probe technique and were able to demonstrate that the response time of such a film is sufficiently short to investigate sub-nanosecond phenomena. Furthermore, we studied the penetration velocity of the dendritic instability in thin YBCO films. We found two regimes: An early stage with a penetration velocity of up to 17Okmls and a distinct later stage were the velocity is lower (= 18 km/s).</dcterms:abstract> <dc:contributor>Bolz, Uwe</dc:contributor> <dc:rights>deposit-license</dc:rights> <dc:date rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2011-03-24T17:53:31Z</dc:date> <dcterms:available rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2011-03-24T17:53:31Z</dcterms:available> <dcterms:rights rdf:resource="https://creativecommons.org/licenses/by-nc-nd/2.0/legalcode"/> <dc:language>eng</dc:language> <dc:creator>Biehler, Björn</dc:creator> <bibo:uri rdf:resource="http://kops.uni-konstanz.de/handle/123456789/9088"/> <dc:creator>Bolz, Uwe</dc:creator> <dc:contributor>Runge, Bernd-Uwe</dc:contributor> <dcterms:bibliographicCitation>First publ. in: Magneto-optical imaging : [proceedings of the NATO Advanced Research Workshop on Magneto-Optical Imaging, Øystese, Norway, 28 - 30 August 2003], pp. 47-52</dcterms:bibliographicCitation> <dcterms:issued>2004</dcterms:issued> <dcterms:title>Magneto-optic Investigation of Magnetic Flux Penetration on a Nanosecond Timescale</dcterms:title> <dc:format>application/pdf</dc:format> <dc:contributor>Leiderer, Paul</dc:contributor> <dc:contributor>Biehler, Björn</dc:contributor> </rdf:Description> </rdf:RDF>

Dateiabrufe seit 01.10.2014 (Informationen über die Zugriffsstatistik)

328_magnoptimag_2004.pdf 42

Das Dokument erscheint in:

deposit-license Solange nicht anders angezeigt, wird die Lizenz wie folgt beschrieben: deposit-license

KOPS Suche


Stöbern

Mein Benutzerkonto