KOPS - Das Institutionelle Repositorium der Universität Konstanz

Temporal Integrity of an Airborne Odor Stimulus is Greatly Affected by Physical Aspects of the Odor Delivery System

Temporal Integrity of an Airborne Odor Stimulus is Greatly Affected by Physical Aspects of the Odor Delivery System

Zitieren

Dateien zu dieser Ressource

Prüfsumme: MD5:ba4fb58022c1aa977f4ad7fe9d7e25ce

VETTER, Richard S., Amy E. SAGE, Kristine A. JUSTUS, Ring T. CARDÉ, Cosmas Giovanni GALIZIA, 2006. Temporal Integrity of an Airborne Odor Stimulus is Greatly Affected by Physical Aspects of the Odor Delivery System. In: Chemical senses. 31(4), pp. 359-369. ISSN 0379-864X. eISSN 1464-3553

@article{Vetter2006Tempo-6993, title={Temporal Integrity of an Airborne Odor Stimulus is Greatly Affected by Physical Aspects of the Odor Delivery System}, year={2006}, number={4}, volume={31}, issn={0379-864X}, journal={Chemical senses}, pages={359--369}, author={Vetter, Richard S. and Sage, Amy E. and Justus, Kristine A. and Cardé, Ring T. and Galizia, Cosmas Giovanni} }

2011-03-24T17:30:42Z Vetter, Richard S. application/pdf Cardé, Ring T. Justus, Kristine A. Cardé, Ring T. Sage, Amy E. Vetter, Richard S. deposit-license Galizia, Cosmas Giovanni First publ. in: Chemical senses 31 (2006), 4, pp. 359-369 Justus, Kristine A. deu There is currently a debate about the role played by temporal patterns in neural activity in olfactory coding. An accurate analysis of this question, however, is only possible if the temporal properties of a stimulus itself are well defined. So far, no technique with sufficient temporal resolution has been available to accomplish this. Using a photoionization detector (PID), we show that the<br />configuration of the odor delivery apparatus and the airflow settings greatly influence the integrity of a stimulus profile within an odor delivery apparatus. In a situation where pulsatile odor stimuli are applied to a stationary preparation, we tested the effect of<br />1) axial and off-center location within the airstream,<br />2) airflow of the odor delivery,<br />3) exit tube length,<br />4) exit tube diameter,<br />5) orientation of the odor delivery device in relation to the exhaust flow, and 6) exhaust tube air speed.<br />This has important implications for the study of time in olfaction; significant planning must be incorporated into the design of the experiment to provide a well-defined odor delivery system. 2011-03-24T17:30:42Z Temporal Integrity of an Airborne Odor Stimulus is Greatly Affected by Physical Aspects of the Odor Delivery System 2006 Galizia, Cosmas Giovanni Sage, Amy E.

Dateiabrufe seit 01.10.2014 (Informationen über die Zugriffsstatistik)

Vetter06_ChemSenses.pdf 156

Das Dokument erscheint in:

KOPS Suche


Stöbern

Mein Benutzerkonto