Designing ergometer tests for the calibration of physiological endurance models

Zitieren

Dateien zu dieser Ressource

Prüfsumme: MD5:732e957abd883f8bcaefec081dd6b073

DAHMEN, Thorsten, 2012. Designing ergometer tests for the calibration of physiological endurance models. WCPAS IX. Worcester, U.K., 25. Jul 2012 - 28. Jul 2012. In: World Congress of Performance Analysis of Sport IX (WCPAS IX), 25th - 28th July 2012, Worcester, U.K.. WCPAS IX. Worcester, U.K., 25. Jul 2012 - 28. Jul 2012

@inproceedings{Dahmen2012Desig-26678, title={Designing ergometer tests for the calibration of physiological endurance models}, year={2012}, booktitle={World Congress of Performance Analysis of Sport IX (WCPAS IX), 25th - 28th July 2012, Worcester, U.K.}, author={Dahmen, Thorsten} }

<rdf:RDF xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:bibo="http://purl.org/ontology/bibo/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:xsd="http://www.w3.org/2001/XMLSchema#" > <rdf:Description rdf:about="https://kops.uni-konstanz.de/rdf/resource/123456789/26678"> <dc:language>eng</dc:language> <dcterms:title>Designing ergometer tests for the calibration of physiological endurance models</dcterms:title> <dc:rights>deposit-license</dc:rights> <dcterms:rights rdf:resource="http://nbn-resolving.org/urn:nbn:de:bsz:352-20140905103605204-4002607-1"/> <dcterms:issued>2012</dcterms:issued> <dcterms:bibliographicCitation>Vortrag gehalten bei: World Congress of Performance Analysis of Sport IX (WCPAS IX), 25th - 28th July 2012, Worcester, U.K.</dcterms:bibliographicCitation> <dc:creator>Dahmen, Thorsten</dc:creator> <dc:contributor>Dahmen, Thorsten</dc:contributor> <bibo:uri rdf:resource="http://kops.uni-konstanz.de/handle/123456789/26678"/> <dcterms:available rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2014-05-28T09:03:04Z</dcterms:available> <dc:date rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2014-05-28T09:03:04Z</dc:date> <dcterms:abstract xml:lang="eng">Physiological endurance models are widely used to characterize the capabilities, limitations, and dynamics of human performance (Morton, 2006). The ircalibration is a classical curve fitting task, where the parameters are chosen to minimize the deviation of model estimations from measurements of performance indicators such as power, heart rate, oxygen consumption,and lactate level for a particular ergometer test. The design of an appropriate ergometer test setup is often based on heuristics and experience of sports scientists. However, the sensitivity of the model parameters with respect to variations of the measurements depends on that design. Here, we focus on the 3- parameter critical power model and present an alternative ergometer test setup, which improves the parameter calibration for the modeling of short intense workload and choose interval lengths to maximize the sensitivity of the parameters</dcterms:abstract> </rdf:Description> </rdf:RDF>

Dateiabrufe seit 01.10.2014 (Informationen über die Zugriffsstatistik)

Dahmen_266784.pdf 64

Das Dokument erscheint in:

KOPS Suche


Stöbern

Mein Benutzerkonto