KOPS - Das Institutionelle Repositorium der Universität Konstanz

In situ contacting and current-injection into samples in photoemission electron microscopes

In situ contacting and current-injection into samples in photoemission electron microscopes

Zitieren

Dateien zu dieser Ressource

Prüfsumme: MD5:c7960314d9b54e2656700a81e5e481f3

HEYNE, Lutz, Mathias KLÄUI, Jan RHENSIUS, Loic LE*GUYADER, Frithjof NOLTING, 2010. In situ contacting and current-injection into samples in photoemission electron microscopes. In: Review of Scientific Instruments. 81(11), 113707. ISSN 0034-6748. eISSN 1089-7623

@article{Heyne2010-11conta-19806, title={In situ contacting and current-injection into samples in photoemission electron microscopes}, year={2010}, doi={10.1063/1.3495967}, number={11}, volume={81}, issn={0034-6748}, journal={Review of Scientific Instruments}, author={Heyne, Lutz and Kläui, Mathias and Rhensius, Jan and Le*Guyader, Loic and Nolting, Frithjof}, note={Article Number: 113707} }

<rdf:RDF xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:bibo="http://purl.org/ontology/bibo/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:xsd="http://www.w3.org/2001/XMLSchema#" > <rdf:Description rdf:about="https://kops.uni-konstanz.de/rdf/resource/123456789/19806"> <dc:contributor>Kläui, Mathias</dc:contributor> <dc:creator>Le*Guyader, Loic</dc:creator> <dc:contributor>Le*Guyader, Loic</dc:contributor> <dc:creator>Nolting, Frithjof</dc:creator> <dc:creator>Rhensius, Jan</dc:creator> <dc:contributor>Heyne, Lutz</dc:contributor> <dc:contributor>Nolting, Frithjof</dc:contributor> <dcterms:abstract xml:lang="eng">Studying the interaction of spin-polarized currents with the magnetization configuration is of high interest due to the possible applications and the novel physics involved. High-resolution magnetic imaging is one of the key techniques necessary for a better understanding of these effects. Here, we present an extension to a magnetic microscope that allows for in situ current injection into the structure investigated, and furthermore for the study of current induced magnetization changes during pulsed current injection. The developed setup is highly flexible and can be used for a wide range of investigations. Examples of current-induced domain wall motion and vortex core displacements measured using this setup are presented.</dcterms:abstract> <dc:creator>Heyne, Lutz</dc:creator> <bibo:uri rdf:resource="http://kops.uni-konstanz.de/handle/123456789/19806"/> <dcterms:bibliographicCitation>First publ. in: Review of Scientific Instruments ; 81 (2010), 11. - 113707</dcterms:bibliographicCitation> <dc:creator>Kläui, Mathias</dc:creator> <dc:date rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2012-07-19T10:25:08Z</dc:date> <dcterms:title>In situ contacting and current-injection into samples in photoemission electron microscopes</dcterms:title> <dc:language>eng</dc:language> <dcterms:rights rdf:resource="http://nbn-resolving.org/urn:nbn:de:bsz:352-20140905103605204-4002607-1"/> <dc:rights>deposit-license</dc:rights> <dcterms:issued>2010-11</dcterms:issued> <dcterms:available rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2012-07-19T10:25:08Z</dcterms:available> <dc:contributor>Rhensius, Jan</dc:contributor> </rdf:Description> </rdf:RDF>

Dateiabrufe seit 01.10.2014 (Informationen über die Zugriffsstatistik)

Heyne_In situ contacting.pdf 84

Das Dokument erscheint in:

KOPS Suche


Stöbern

Mein Benutzerkonto