Detection of very low-frequency oscillations of cerebral haemodynamics is influenced by data detrending
| dc.contributor.author | Müller, Thomas | |
| dc.contributor.author | Timmer, Jens | deu |
| dc.contributor.author | Reinhard, Matthias | deu |
| dc.contributor.author | Oehm, Eckard | deu |
| dc.contributor.author | Hetzel, Andreas | deu |
| dc.date.accessioned | 2014-04-14T12:10:38Z | deu |
| dc.date.available | 2014-04-14T12:10:38Z | deu |
| dc.date.issued | 2003 | |
| dc.description.abstract | Recent studies were investigated that report spontaneous oscillations of cerebral perfusion in the very low-frequency range (0.01-0.04 Hz), emphasising details of spectral estimation. The effects of different spectral estimation procedures were compared, using simulated and clinical data. It was shown that data detrending, as used in many studies, can lead to an artifactual peak in the very low-frequency region of estimated power spectra, indicating that the peak cannot be taken as evidence of physiological oscillations. A quantitative, reliable method is described that can be used to assess very low-frequency oscillations. Using the method, very low-frequency oscillations were found in ten out of 17 healthy adults measured with transcranial Doppler (average frequency, 0.021 +/- 0.007 Hz, mean +/- SD), confirming earlier findings based on visual inspection of data. | eng |
| dc.description.version | published | |
| dc.identifier.citation | Medical & biological engineering & computing ; 41 (2003), 1. - S. 69-74 | deu |
| dc.identifier.doi | 10.1007/BF02343541 | deu |
| dc.identifier.ppn | 404411231 | deu |
| dc.identifier.uri | http://kops.uni-konstanz.de/handle/123456789/27254 | |
| dc.language.iso | eng | deu |
| dc.legacy.dateIssued | 2014-04-14 | deu |
| dc.rights | terms-of-use | deu |
| dc.rights.uri | https://rightsstatements.org/page/InC/1.0/ | deu |
| dc.subject | Adult | deu |
| dc.subject | Artifacts | deu |
| dc.subject | Blood Flow Velocity | deu |
| dc.subject | Cerebrovascular Circulation | deu |
| dc.subject | Female | deu |
| dc.subject | Hemodynamics | deu |
| dc.subject | Humans | deu |
| dc.subject | Male | deu |
| dc.subject | Signal Processing | deu |
| dc.subject | Computer-Assisted | deu |
| dc.subject | Ultrasonography | deu |
| dc.subject | Doppler | deu |
| dc.subject | Transcranial | deu |
| dc.subject.ddc | 100 | deu |
| dc.title | Detection of very low-frequency oscillations of cerebral haemodynamics is influenced by data detrending | eng |
| dc.type | JOURNAL_ARTICLE | deu |
| dspace.entity.type | Publication | |
| kops.citation.bibtex | @article{Muller2003Detec-27254,
year={2003},
doi={10.1007/BF02343541},
title={Detection of very low-frequency oscillations of cerebral haemodynamics is influenced by data detrending},
number={1},
volume={41},
issn={0140-0118},
journal={Medical & Biological Engineering & Computing},
pages={69--74},
author={Müller, Thomas and Timmer, Jens and Reinhard, Matthias and Oehm, Eckard and Hetzel, Andreas}
} | |
| kops.citation.iso690 | MÜLLER, Thomas, Jens TIMMER, Matthias REINHARD, Eckard OEHM, Andreas HETZEL, 2003. Detection of very low-frequency oscillations of cerebral haemodynamics is influenced by data detrending. In: Medical & Biological Engineering & Computing. 2003, 41(1), pp. 69-74. ISSN 0140-0118. eISSN 1741-0444. Available under: doi: 10.1007/BF02343541 | deu |
| kops.citation.iso690 | MÜLLER, Thomas, Jens TIMMER, Matthias REINHARD, Eckard OEHM, Andreas HETZEL, 2003. Detection of very low-frequency oscillations of cerebral haemodynamics is influenced by data detrending. In: Medical & Biological Engineering & Computing. 2003, 41(1), pp. 69-74. ISSN 0140-0118. eISSN 1741-0444. Available under: doi: 10.1007/BF02343541 | eng |
| kops.citation.rdf | <rdf:RDF
xmlns:dcterms="http://purl.org/dc/terms/"
xmlns:dc="http://purl.org/dc/elements/1.1/"
xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#"
xmlns:bibo="http://purl.org/ontology/bibo/"
xmlns:dspace="http://digital-repositories.org/ontologies/dspace/0.1.0#"
xmlns:foaf="http://xmlns.com/foaf/0.1/"
xmlns:void="http://rdfs.org/ns/void#"
xmlns:xsd="http://www.w3.org/2001/XMLSchema#" >
<rdf:Description rdf:about="https://kops.uni-konstanz.de/server/rdf/resource/123456789/27254">
<void:sparqlEndpoint rdf:resource="http://localhost/fuseki/dspace/sparql"/>
<dc:contributor>Hetzel, Andreas</dc:contributor>
<dcterms:hasPart rdf:resource="https://kops.uni-konstanz.de/bitstream/123456789/27254/1/Mueller_272545.pdf"/>
<dcterms:abstract xml:lang="eng">Recent studies were investigated that report spontaneous oscillations of cerebral perfusion in the very low-frequency range (0.01-0.04 Hz), emphasising details of spectral estimation. The effects of different spectral estimation procedures were compared, using simulated and clinical data. It was shown that data detrending, as used in many studies, can lead to an artifactual peak in the very low-frequency region of estimated power spectra, indicating that the peak cannot be taken as evidence of physiological oscillations. A quantitative, reliable method is described that can be used to assess very low-frequency oscillations. Using the method, very low-frequency oscillations were found in ten out of 17 healthy adults measured with transcranial Doppler (average frequency, 0.021 +/- 0.007 Hz, mean +/- SD), confirming earlier findings based on visual inspection of data.</dcterms:abstract>
<dcterms:title>Detection of very low-frequency oscillations of cerebral haemodynamics is influenced by data detrending</dcterms:title>
<dcterms:isPartOf rdf:resource="https://kops.uni-konstanz.de/server/rdf/resource/123456789/40"/>
<dcterms:available rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2014-04-14T12:10:38Z</dcterms:available>
<dc:creator>Müller, Thomas</dc:creator>
<foaf:homepage rdf:resource="http://localhost:8080/"/>
<dc:contributor>Müller, Thomas</dc:contributor>
<bibo:uri rdf:resource="http://kops.uni-konstanz.de/handle/123456789/27254"/>
<dc:contributor>Timmer, Jens</dc:contributor>
<dc:rights>terms-of-use</dc:rights>
<dc:creator>Oehm, Eckard</dc:creator>
<dcterms:bibliographicCitation>Medical & biological engineering & computing ; 41 (2003), 1. - S. 69-74</dcterms:bibliographicCitation>
<dcterms:rights rdf:resource="https://rightsstatements.org/page/InC/1.0/"/>
<dc:contributor>Oehm, Eckard</dc:contributor>
<dc:contributor>Reinhard, Matthias</dc:contributor>
<dspace:hasBitstream rdf:resource="https://kops.uni-konstanz.de/bitstream/123456789/27254/1/Mueller_272545.pdf"/>
<dc:creator>Reinhard, Matthias</dc:creator>
<dcterms:issued>2003</dcterms:issued>
<dspace:isPartOfCollection rdf:resource="https://kops.uni-konstanz.de/server/rdf/resource/123456789/40"/>
<dc:language>eng</dc:language>
<dc:creator>Hetzel, Andreas</dc:creator>
<dc:creator>Timmer, Jens</dc:creator>
<dc:date rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2014-04-14T12:10:38Z</dc:date>
</rdf:Description>
</rdf:RDF> | |
| kops.description.openAccess | openaccessgreen | |
| kops.flag.knbibliography | false | |
| kops.identifier.nbn | urn:nbn:de:bsz:352-272545 | deu |
| kops.sourcefield | Medical & Biological Engineering & Computing. 2003, <b>41</b>(1), pp. 69-74. ISSN 0140-0118. eISSN 1741-0444. Available under: doi: 10.1007/BF02343541 | deu |
| kops.sourcefield.plain | Medical & Biological Engineering & Computing. 2003, 41(1), pp. 69-74. ISSN 0140-0118. eISSN 1741-0444. Available under: doi: 10.1007/BF02343541 | deu |
| kops.sourcefield.plain | Medical & Biological Engineering & Computing. 2003, 41(1), pp. 69-74. ISSN 0140-0118. eISSN 1741-0444. Available under: doi: 10.1007/BF02343541 | eng |
| kops.submitter.email | malte.stackebrandt@uni-konstanz.de | deu |
| relation.isAuthorOfPublication | 63074fc8-db93-42c7-afb8-32486f9fcacc | |
| relation.isAuthorOfPublication.latestForDiscovery | 63074fc8-db93-42c7-afb8-32486f9fcacc | |
| source.bibliographicInfo.fromPage | 69 | |
| source.bibliographicInfo.issue | 1 | |
| source.bibliographicInfo.toPage | 74 | |
| source.bibliographicInfo.volume | 41 | |
| source.identifier.eissn | 1741-0444 | deu |
| source.identifier.issn | 0140-0118 | |
| source.periodicalTitle | Medical & Biological Engineering & Computing |
Dateien
Originalbündel
1 - 1 von 1
Vorschaubild nicht verfügbar
- Name:
- Mueller_272545.pdf
- Größe:
- 1.46 MB
- Format:
- Adobe Portable Document Format
Lizenzbündel
1 - 1 von 1
Vorschaubild nicht verfügbar
- Name:
- license.txt
- Größe:
- 1.92 KB
- Format:
- Plain Text
- Beschreibung: