Next-Generation AUC Adds a Spectral Dimension : Development of Multiwavelength Detectors for the Analytical Ultracentrifuge
| dc.contributor.author | Pearson, Joseph | |
| dc.contributor.author | Krause, Frank | |
| dc.contributor.author | Haffke, Dirk | |
| dc.contributor.author | Demeler, Borries | |
| dc.contributor.author | Schilling, Kristian | |
| dc.contributor.author | Cölfen, Helmut | |
| dc.date.accessioned | 2015-11-24T13:43:12Z | |
| dc.date.available | 2015-11-24T13:43:12Z | |
| dc.date.issued | 2015 | eng |
| dc.description.abstract | We describe important advances in analytical ultracentrifugation (AUC) hardware, which add new information to the hydrodynamic information observed in traditional AUC instruments. In contrast to the Beckman-Coulter XLA UV/visible detector, multiwavelength (MWL) detection is able to collect sedimentation data not just for one wavelength, but for a large wavelength range in a single experiment. The additional dimension increases the data density by orders of magnitude, significantly improving the statistics of the measurement and adding important information to the experiment since an additional dimension of spectral characterization is now available to complement the hydrodynamic information. The new detector avoids tedious repeats of experiments at different wavelengths and opens up new avenues for the solution-based investigation of complex mixtures. In this chapter, we describe the capabilities, characteristics, and applications of the new detector design with biopolymers as the focus of study. We show data from two different MWL detectors and discuss strengths and weaknesses of differences in the hardware and different data acquisition modes. Also, difficulties with fiber optic applications in the UV are discussed. Data quality is compared across platforms. | eng |
| dc.description.version | published | eng |
| dc.identifier.doi | 10.1016/bs.mie.2015.06.033 | eng |
| dc.identifier.uri | https://kops.uni-konstanz.de/handle/123456789/32236 | |
| dc.language.iso | eng | eng |
| dc.subject | Analytical ultracentrifugation; Multiwavelength detector; UV-vis absorbance; Optical detector development; Hydrodynamic analysis; Spectral analysis | eng |
| dc.subject.ddc | 540 | eng |
| dc.title | Next-Generation AUC Adds a Spectral Dimension : Development of Multiwavelength Detectors for the Analytical Ultracentrifuge | eng |
| dc.type | INCOLLECTION | eng |
| dspace.entity.type | Publication | |
| kops.citation.bibtex | @incollection{Pearson2015NextG-32236,
year={2015},
doi={10.1016/bs.mie.2015.06.033},
title={Next-Generation AUC Adds a Spectral Dimension : Development of Multiwavelength Detectors for the Analytical Ultracentrifuge},
url={http://www.sciencedirect.com/science/article/pii/S0076687915003936},
number={562},
isbn={978-0-12-802908-4},
publisher={Academic Press [u.a.]},
address={Amsterdam [u.a.]},
series={Methods in enzymology},
booktitle={Analytical ultracentrifugation},
pages={1--26},
editor={Cole, James L.},
author={Pearson, Joseph and Krause, Frank and Haffke, Dirk and Demeler, Borries and Schilling, Kristian and Cölfen, Helmut}
} | |
| kops.citation.iso690 | PEARSON, Joseph, Frank KRAUSE, Dirk HAFFKE, Borries DEMELER, Kristian SCHILLING, Helmut CÖLFEN, 2015. Next-Generation AUC Adds a Spectral Dimension : Development of Multiwavelength Detectors for the Analytical Ultracentrifuge. In: COLE, James L., ed.. Analytical ultracentrifugation. Amsterdam [u.a.]: Academic Press [u.a.], 2015, pp. 1-26. Methods in enzymology. 562. ISBN 978-0-12-802908-4. Available under: doi: 10.1016/bs.mie.2015.06.033 | deu |
| kops.citation.iso690 | PEARSON, Joseph, Frank KRAUSE, Dirk HAFFKE, Borries DEMELER, Kristian SCHILLING, Helmut CÖLFEN, 2015. Next-Generation AUC Adds a Spectral Dimension : Development of Multiwavelength Detectors for the Analytical Ultracentrifuge. In: COLE, James L., ed.. Analytical ultracentrifugation. Amsterdam [u.a.]: Academic Press [u.a.], 2015, pp. 1-26. Methods in enzymology. 562. ISBN 978-0-12-802908-4. Available under: doi: 10.1016/bs.mie.2015.06.033 | eng |
| kops.citation.rdf | <rdf:RDF
xmlns:dcterms="http://purl.org/dc/terms/"
xmlns:dc="http://purl.org/dc/elements/1.1/"
xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#"
xmlns:bibo="http://purl.org/ontology/bibo/"
xmlns:dspace="http://digital-repositories.org/ontologies/dspace/0.1.0#"
xmlns:foaf="http://xmlns.com/foaf/0.1/"
xmlns:void="http://rdfs.org/ns/void#"
xmlns:xsd="http://www.w3.org/2001/XMLSchema#" >
<rdf:Description rdf:about="https://kops.uni-konstanz.de/server/rdf/resource/123456789/32236">
<dc:date rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2015-11-24T13:43:12Z</dc:date>
<dcterms:available rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2015-11-24T13:43:12Z</dcterms:available>
<dc:creator>Schilling, Kristian</dc:creator>
<dcterms:title>Next-Generation AUC Adds a Spectral Dimension : Development of Multiwavelength Detectors for the Analytical Ultracentrifuge</dcterms:title>
<dc:contributor>Cölfen, Helmut</dc:contributor>
<dc:creator>Haffke, Dirk</dc:creator>
<dcterms:isPartOf rdf:resource="https://kops.uni-konstanz.de/server/rdf/resource/123456789/29"/>
<void:sparqlEndpoint rdf:resource="http://localhost/fuseki/dspace/sparql"/>
<dc:contributor>Schilling, Kristian</dc:contributor>
<dc:creator>Krause, Frank</dc:creator>
<dc:contributor>Haffke, Dirk</dc:contributor>
<dc:contributor>Pearson, Joseph</dc:contributor>
<dc:creator>Demeler, Borries</dc:creator>
<dc:creator>Cölfen, Helmut</dc:creator>
<foaf:homepage rdf:resource="http://localhost:8080/"/>
<bibo:uri rdf:resource="https://kops.uni-konstanz.de/handle/123456789/32236"/>
<dc:language>eng</dc:language>
<dcterms:abstract xml:lang="eng">We describe important advances in analytical ultracentrifugation (AUC) hardware, which add new information to the hydrodynamic information observed in traditional AUC instruments. In contrast to the Beckman-Coulter XLA UV/visible detector, multiwavelength (MWL) detection is able to collect sedimentation data not just for one wavelength, but for a large wavelength range in a single experiment. The additional dimension increases the data density by orders of magnitude, significantly improving the statistics of the measurement and adding important information to the experiment since an additional dimension of spectral characterization is now available to complement the hydrodynamic information. The new detector avoids tedious repeats of experiments at different wavelengths and opens up new avenues for the solution-based investigation of complex mixtures. In this chapter, we describe the capabilities, characteristics, and applications of the new detector design with biopolymers as the focus of study. We show data from two different MWL detectors and discuss strengths and weaknesses of differences in the hardware and different data acquisition modes. Also, difficulties with fiber optic applications in the UV are discussed. Data quality is compared across platforms.</dcterms:abstract>
<dspace:isPartOfCollection rdf:resource="https://kops.uni-konstanz.de/server/rdf/resource/123456789/29"/>
<dc:creator>Pearson, Joseph</dc:creator>
<dc:contributor>Krause, Frank</dc:contributor>
<dcterms:issued>2015</dcterms:issued>
<dc:contributor>Demeler, Borries</dc:contributor>
</rdf:Description>
</rdf:RDF> | |
| kops.flag.knbibliography | true | |
| kops.sourcefield | COLE, James L., ed.. <i>Analytical ultracentrifugation</i>. Amsterdam [u.a.]: Academic Press [u.a.], 2015, pp. 1-26. Methods in enzymology. 562. ISBN 978-0-12-802908-4. Available under: doi: 10.1016/bs.mie.2015.06.033 | deu |
| kops.sourcefield.plain | COLE, James L., ed.. Analytical ultracentrifugation. Amsterdam [u.a.]: Academic Press [u.a.], 2015, pp. 1-26. Methods in enzymology. 562. ISBN 978-0-12-802908-4. Available under: doi: 10.1016/bs.mie.2015.06.033 | deu |
| kops.sourcefield.plain | COLE, James L., ed.. Analytical ultracentrifugation. Amsterdam [u.a.]: Academic Press [u.a.], 2015, pp. 1-26. Methods in enzymology. 562. ISBN 978-0-12-802908-4. Available under: doi: 10.1016/bs.mie.2015.06.033 | eng |
| kops.url | http://www.sciencedirect.com/science/article/pii/S0076687915003936 | eng |
| kops.urlDate | 2015-11-24 | eng |
| relation.isAuthorOfPublication | 340cbf22-6a86-49a6-b7aa-2ed6205c57be | |
| relation.isAuthorOfPublication | 4f008ee5-95ec-432c-a15a-250fb6f4e7e7 | |
| relation.isAuthorOfPublication | 4bb493dd-f4c7-4ece-aab9-913000b58820 | |
| relation.isAuthorOfPublication.latestForDiscovery | 340cbf22-6a86-49a6-b7aa-2ed6205c57be | |
| source.bibliographicInfo.fromPage | 1 | eng |
| source.bibliographicInfo.seriesNumber | 562 | eng |
| source.bibliographicInfo.toPage | 26 | eng |
| source.contributor.editor | Cole, James L. | eng |
| source.identifier.isbn | 978-0-12-802908-4 | eng |
| source.publisher | Academic Press [u.a.] | eng |
| source.publisher.location | Amsterdam [u.a.] | eng |
| source.relation.ispartofseries | Methods in enzymology | eng |
| source.title | Analytical ultracentrifugation | eng |
Dateien
Lizenzbündel
1 - 1 von 1
Vorschaubild nicht verfügbar
- Name:
- license.txt
- Größe:
- 3.88 KB
- Format:
- Item-specific license agreed upon to submission
- Beschreibung: