Relation of Accelerometer and EMG Recordings for the Measurement of Upper Extremity Movement

Loading...
Thumbnail Image
Date
1999
Authors
Keil, Andreas
Taub, Edward
Editors
Contact
Journal ISSN
Electronic ISSN
ISBN
Bibliographical data
Publisher
Series
DOI (citable link)
ArXiv-ID
International patent number
EU project number
Project
Open Access publication
Collections
Restricted until
Title in another language
Research Projects
Organizational Units
Journal Issue
Publication type
Journal article
Publication status
Published in
Journal of Psychophysiology ; 13 (1999), 2. - pp. 77-82
Abstract
In order to determine the value of accelerometry as a measure of real world outcome when a subject is outside the laboratory, accelerometer recordings from the wrist were compared with simultaneous electromyogram (EMG) recordings from the lower and upper arm. Accelerometer and EMG signals were recorded simultaneously by the Kölner Vitaport System , an ambulatory device. Six male subjects performed standardized tasks as well as activities of daily life (ADL). Low correlations between accelerometer counts and integrated EMG were found in the standardized tasks, whereas there were considerably higher correlations for ADL. However, there was a strong relation between several parameters derived from EMG and accelerometer recordings. The two techniques appear to measure different aspects of movement and may be complementary.
Summary in another language
Subject (DDC)
150 Psychology
Keywords
Accelerometry,electromyography,ambulatory monitoring,activities of daily life,standardized movements
Conference
Review
undefined / . - undefined, undefined. - (undefined; undefined)
Cite This
ISO 690KEIL, Andreas, Thomas ELBERT, Edward TAUB, 1999. Relation of Accelerometer and EMG Recordings for the Measurement of Upper Extremity Movement. In: Journal of Psychophysiology. 13(2), pp. 77-82. Available under: doi: 10.1027//0269-8803.13.2.77
BibTex
@article{Keil1999Relat-10894,
  year={1999},
  doi={10.1027//0269-8803.13.2.77},
  title={Relation of Accelerometer and EMG Recordings for the Measurement of Upper Extremity Movement},
  number={2},
  volume={13},
  journal={Journal of Psychophysiology},
  pages={77--82},
  author={Keil, Andreas and Elbert, Thomas and Taub, Edward}
}
RDF
<rdf:RDF
    xmlns:dcterms="http://purl.org/dc/terms/"
    xmlns:dc="http://purl.org/dc/elements/1.1/"
    xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#"
    xmlns:bibo="http://purl.org/ontology/bibo/"
    xmlns:dspace="http://digital-repositories.org/ontologies/dspace/0.1.0#"
    xmlns:foaf="http://xmlns.com/foaf/0.1/"
    xmlns:void="http://rdfs.org/ns/void#"
    xmlns:xsd="http://www.w3.org/2001/XMLSchema#" > 
  <rdf:Description rdf:about="https://kops.uni-konstanz.de/server/rdf/resource/123456789/10894">
    <foaf:homepage rdf:resource="http://localhost:8080/"/>
    <dcterms:issued>1999</dcterms:issued>
    <dc:contributor>Keil, Andreas</dc:contributor>
    <dcterms:rights rdf:resource="http://creativecommons.org/licenses/by-nc-nd/2.0/"/>
    <dc:creator>Taub, Edward</dc:creator>
    <dc:contributor>Taub, Edward</dc:contributor>
    <dc:contributor>Elbert, Thomas</dc:contributor>
    <dc:creator>Keil, Andreas</dc:creator>
    <dc:language>eng</dc:language>
    <dspace:hasBitstream rdf:resource="https://kops.uni-konstanz.de/bitstream/123456789/10894/1/Relation_of_Accelerometer_and_EMG_Recordings_for_the_Measurement_of_Upper_Extremity_Movement.pdf"/>
    <dc:rights>Attribution-NonCommercial-NoDerivs 2.0 Generic</dc:rights>
    <dcterms:available rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2011-03-25T09:23:38Z</dcterms:available>
    <dcterms:isPartOf rdf:resource="https://kops.uni-konstanz.de/server/rdf/resource/123456789/43"/>
    <void:sparqlEndpoint rdf:resource="http://localhost/fuseki/dspace/sparql"/>
    <dcterms:hasPart rdf:resource="https://kops.uni-konstanz.de/bitstream/123456789/10894/1/Relation_of_Accelerometer_and_EMG_Recordings_for_the_Measurement_of_Upper_Extremity_Movement.pdf"/>
    <dcterms:abstract xml:lang="eng">In order to determine the value of accelerometry as a measure of real world outcome when a subject is outside the laboratory, accelerometer recordings from the wrist were compared with simultaneous electromyogram (EMG) recordings from the lower and upper arm. Accelerometer and EMG signals were recorded simultaneously by the  Kölner Vitaport System , an ambulatory device. Six male subjects performed standardized tasks as well as activities of daily life (ADL). Low correlations between accelerometer counts and integrated EMG were found in the standardized tasks, whereas there were considerably higher correlations for ADL. However, there was a strong relation between several parameters derived from EMG and accelerometer recordings. The two techniques appear to measure different aspects of movement and may be complementary.</dcterms:abstract>
    <dc:format>application/pdf</dc:format>
    <dcterms:title>Relation of Accelerometer and EMG Recordings for the Measurement of Upper Extremity Movement</dcterms:title>
    <dspace:isPartOfCollection rdf:resource="https://kops.uni-konstanz.de/server/rdf/resource/123456789/43"/>
    <bibo:uri rdf:resource="http://kops.uni-konstanz.de/handle/123456789/10894"/>
    <dc:creator>Elbert, Thomas</dc:creator>
    <dc:date rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2011-03-25T09:23:38Z</dc:date>
    <dcterms:bibliographicCitation>First publ. in: Journal of Psychophysiology 13 (1999), 2, pp. 77 82</dcterms:bibliographicCitation>
  </rdf:Description>
</rdf:RDF>
Internal note
xmlui.Submission.submit.DescribeStep.inputForms.label.kops_note_fromSubmitter
Contact
URL of original publication
Test date of URL
Examination date of dissertation
Method of financing
Comment on publication
Alliance license
Corresponding Authors der Uni Konstanz vorhanden
International Co-Authors
Bibliography of Konstanz
No
Refereed