Changes in knee adduction moment, pain, and functionality with a variable-stiffness walking shoe after 6 months

Lade...
Vorschaubild
Dateien
Zu diesem Dokument gibt es keine Dateien.
Datum
2010
Autor:innen
Erhart, Jennifer C.
Elspas, Barbara
Giori, Nick J.
Andriacchi, Thomas P.
Herausgeber:innen
Kontakt
ISSN der Zeitschrift
Electronic ISSN
ISBN
Bibliografische Daten
Verlag
Schriftenreihe
Auflagebezeichnung
DOI (zitierfähiger Link)
ArXiv-ID
Internationale Patentnummer
Angaben zur Forschungsförderung
Projekt
Open Access-Veröffentlichung
Core Facility der Universität Konstanz
Gesperrt bis
Titel in einer weiteren Sprache
Publikationstyp
Zeitschriftenartikel
Publikationsstatus
Published
Erschienen in
Journal of Orthopaedic Research. 2010, 28(7), pp. 873-879. ISSN 0736-0266. eISSN 1554-527X. Available under: doi: 10.1002/jor.21077
Zusammenfassung

This study tested the effects of variable-stiffness shoes on knee adduction moment, pain, and function in subjects with symptoms of medial compartment knee osteoarthritis over 6 months. Patients were randomly and blindly assigned to a variable-stiffness intervention or constant-stiffness control shoe. The Western Ontario and McMaster Universities (WOMAC) score served as the primary outcome measure. Joint loading, the secondary outcome measure, was assessed using the external knee adduction moment. Peak external knee adduction moment, total WOMAC, and WOMAC pain scores were assessed at baseline and after 6 months. The total WOMAC and WOMAC pain scores for the intervention group were reduced from baseline to 6 months (p 1⁄4 0.017 and p 1⁄4 0.002, respectively), with no significant reductions for the control group. There was no difference between groups in magnitude of the reduction in total WOMAC (p 1⁄4 0.50) or WOMAC pain scores (p 1⁄4 0.31). The proportion of patients achieving a clinically important improvement in pain was greater in the intervention group than in the control group (p 1⁄4 0.012). The variable-stiffness shoes reduced the peak knee adduction moment (-6.6% vs. control, p < 0.001) in the 34 intervention subjects at 6 months. The adduction moment reduction significantly improved (p 1⁄4 0.03) from the baseline reduction. The constant-stiffness control shoe increased the peak knee adduction moment (þ6.3% vs. personal, p 1⁄4 0.004) in the 26 control subjects at 6 months. The results of this study showed that wearing the variable-stiffness shoe lowered the adduction moment, reduced pain, and improved functionality after 6 months of wear. The lower adduction moment associated with wearing this shoe may slow the rate of progression of osteoarthritis after long-term use.

Zusammenfassung in einer weiteren Sprache
Fachgebiet (DDC)
796 Sport
Schlagwörter
Konferenz
Rezension
undefined / . - undefined, undefined
Forschungsvorhaben
Organisationseinheiten
Zeitschriftenheft
Datensätze
Zitieren
ISO 690ERHART, Jennifer C., Annegret MÜNDERMANN, Barbara ELSPAS, Nick J. GIORI, Thomas P. ANDRIACCHI, 2010. Changes in knee adduction moment, pain, and functionality with a variable-stiffness walking shoe after 6 months. In: Journal of Orthopaedic Research. 2010, 28(7), pp. 873-879. ISSN 0736-0266. eISSN 1554-527X. Available under: doi: 10.1002/jor.21077
BibTex
@article{Erhart2010-07Chang-17820,
  year={2010},
  doi={10.1002/jor.21077},
  title={Changes in knee adduction moment, pain, and functionality with a variable-stiffness walking shoe after 6 months},
  number={7},
  volume={28},
  issn={0736-0266},
  journal={Journal of Orthopaedic Research},
  pages={873--879},
  author={Erhart, Jennifer C. and Mündermann, Annegret and Elspas, Barbara and Giori, Nick J. and Andriacchi, Thomas P.}
}
RDF
<rdf:RDF
    xmlns:dcterms="http://purl.org/dc/terms/"
    xmlns:dc="http://purl.org/dc/elements/1.1/"
    xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#"
    xmlns:bibo="http://purl.org/ontology/bibo/"
    xmlns:dspace="http://digital-repositories.org/ontologies/dspace/0.1.0#"
    xmlns:foaf="http://xmlns.com/foaf/0.1/"
    xmlns:void="http://rdfs.org/ns/void#"
    xmlns:xsd="http://www.w3.org/2001/XMLSchema#" > 
  <rdf:Description rdf:about="https://kops.uni-konstanz.de/server/rdf/resource/123456789/17820">
    <dcterms:abstract xml:lang="eng">This study tested the effects of variable-stiffness shoes on knee adduction moment, pain, and function in subjects with symptoms of medial compartment knee osteoarthritis over 6 months. Patients were randomly and blindly assigned to a variable-stiffness intervention or constant-stiffness control shoe. The Western Ontario and McMaster Universities (WOMAC) score served as the primary outcome measure. Joint loading, the secondary outcome measure, was assessed using the external knee adduction moment. Peak external knee adduction moment, total WOMAC, and WOMAC pain scores were assessed at baseline and after 6 months. The total WOMAC and WOMAC pain scores for the intervention group were reduced from baseline to 6 months (p 1⁄4 0.017 and p 1⁄4 0.002, respectively), with no significant reductions for the control group. There was no difference between groups in magnitude of the reduction in total WOMAC (p 1⁄4 0.50) or WOMAC pain scores (p 1⁄4 0.31). The proportion of patients achieving a clinically important improvement in pain was greater in the intervention group than in the control group (p 1⁄4 0.012). The variable-stiffness shoes reduced the peak knee adduction moment (-6.6% vs. control, p &lt; 0.001) in the 34 intervention subjects at 6 months. The adduction moment reduction significantly improved (p 1⁄4 0.03) from the baseline reduction. The constant-stiffness control shoe increased the peak knee adduction moment (þ6.3% vs. personal, p 1⁄4 0.004) in the 26 control subjects at 6 months. The results of this study showed that wearing the variable-stiffness shoe lowered the adduction moment, reduced pain, and improved functionality after 6 months of wear. The lower adduction moment associated with wearing this shoe may slow the rate of progression of osteoarthritis after long-term use.</dcterms:abstract>
    <dc:creator>Elspas, Barbara</dc:creator>
    <dc:contributor>Andriacchi, Thomas P.</dc:contributor>
    <dc:contributor>Elspas, Barbara</dc:contributor>
    <dc:date rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2012-02-03T08:26:12Z</dc:date>
    <bibo:uri rdf:resource="http://kops.uni-konstanz.de/handle/123456789/17820"/>
    <dspace:isPartOfCollection rdf:resource="https://kops.uni-konstanz.de/server/rdf/resource/123456789/35"/>
    <dc:contributor>Giori, Nick J.</dc:contributor>
    <dc:rights>terms-of-use</dc:rights>
    <void:sparqlEndpoint rdf:resource="http://localhost/fuseki/dspace/sparql"/>
    <dc:creator>Giori, Nick J.</dc:creator>
    <dcterms:available rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2012-02-03T08:26:12Z</dcterms:available>
    <dc:language>eng</dc:language>
    <dcterms:bibliographicCitation>Publ. in: Journal of Orthopaedic Research ; 28 (2010), 7. - S. 873-879</dcterms:bibliographicCitation>
    <dc:contributor>Mündermann, Annegret</dc:contributor>
    <dcterms:issued>2010-07</dcterms:issued>
    <dc:creator>Andriacchi, Thomas P.</dc:creator>
    <dc:contributor>Erhart, Jennifer C.</dc:contributor>
    <foaf:homepage rdf:resource="http://localhost:8080/"/>
    <dc:creator>Mündermann, Annegret</dc:creator>
    <dcterms:title>Changes in knee adduction moment, pain, and functionality with a variable-stiffness walking shoe after 6 months</dcterms:title>
    <dcterms:isPartOf rdf:resource="https://kops.uni-konstanz.de/server/rdf/resource/123456789/35"/>
    <dc:creator>Erhart, Jennifer C.</dc:creator>
    <dcterms:rights rdf:resource="https://rightsstatements.org/page/InC/1.0/"/>
  </rdf:Description>
</rdf:RDF>
Interner Vermerk
xmlui.Submission.submit.DescribeStep.inputForms.label.kops_note_fromSubmitter
Kontakt
URL der Originalveröffentl.
Prüfdatum der URL
Prüfungsdatum der Dissertation
Finanzierungsart
Kommentar zur Publikation
Allianzlizenz
Corresponding Authors der Uni Konstanz vorhanden
Internationale Co-Autor:innen
Universitätsbibliographie
Ja
Begutachtet
Diese Publikation teilen