Publikation: Directional lithium hydride Compton profiles of 0.1% statistical accuracy
Dateien
Datum
Autor:innen
Herausgeber:innen
ISSN der Zeitschrift
Electronic ISSN
ISBN
Bibliografische Daten
Verlag
Schriftenreihe
Auflagebezeichnung
DOI (zitierfähiger Link)
Internationale Patentnummer
Angaben zur Forschungsförderung
Projekt
Open Access-Veröffentlichung
Sammlungen
Core Facility der Universität Konstanz
Titel in einer weiteren Sprache
Publikationstyp
Publikationsstatus
Erschienen in
Zusammenfassung
The present status and accuracy of determining the electron momentum density from experimental Compton profiles is reviewed. The new spectrometers operating at third-generation synchrotron radiation sources have made possible measurements with 0.1% statistical accuracy at the Compton peak. A comparable accuracy of the Compton profiles is achieved only after careful corrections for departures from the impulse approximation, effects of multiple scattering, and variations in the analyser response function. Detailed descriptions are given of the correction procedures applied to the data collected by the Johann-type scanning spectrometer that is one of the Compton spectrometers in use at the ESRF. Special attention is paid to the calculation and correction of the glitches that are caused by extra reflections of the analyser crystal. The Fourier transform of the Compton profile, the reciprocal form factor, is calculated, and its use in data treatment and presentation is discussed.
Zusammenfassung in einer weiteren Sprache
Fachgebiet (DDC)
Schlagwörter
Konferenz
Rezension
Zitieren
ISO 690
HUOTARI, Simo, Barbara BOLDRINI, Veijo HONKIMÄKI, Pekka SUORTTI, Wolf WEYRICH, 2009. Directional lithium hydride Compton profiles of 0.1% statistical accuracy. In: Journal of Synchrotron Radiation. International Union of Crystallography (IUCr). 2009, 16(5), pp. 672-682. ISSN 0909-0495. eISSN 1600-5775. Available under: doi: 10.1107/S0909049509029112BibTex
@article{Huotari2009-09Direc-58211, year={2009}, doi={10.1107/S0909049509029112}, title={Directional lithium hydride Compton profiles of 0.1% statistical accuracy}, number={5}, volume={16}, issn={0909-0495}, journal={Journal of Synchrotron Radiation}, pages={672--682}, author={Huotari, Simo and Boldrini, Barbara and Honkimäki, Veijo and Suortti, Pekka and Weyrich, Wolf} }
RDF
<rdf:RDF xmlns:dcterms="http://purl.org/dc/terms/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:bibo="http://purl.org/ontology/bibo/" xmlns:dspace="http://digital-repositories.org/ontologies/dspace/0.1.0#" xmlns:foaf="http://xmlns.com/foaf/0.1/" xmlns:void="http://rdfs.org/ns/void#" xmlns:xsd="http://www.w3.org/2001/XMLSchema#" > <rdf:Description rdf:about="https://kops.uni-konstanz.de/server/rdf/resource/123456789/58211"> <dc:date rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2022-07-29T08:30:12Z</dc:date> <dc:language>eng</dc:language> <dspace:isPartOfCollection rdf:resource="https://kops.uni-konstanz.de/server/rdf/resource/123456789/29"/> <dc:contributor>Weyrich, Wolf</dc:contributor> <dc:creator>Weyrich, Wolf</dc:creator> <foaf:homepage rdf:resource="http://localhost:8080/"/> <dc:contributor>Honkimäki, Veijo</dc:contributor> <dc:creator>Honkimäki, Veijo</dc:creator> <dcterms:available rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2022-07-29T08:30:12Z</dcterms:available> <dcterms:isPartOf rdf:resource="https://kops.uni-konstanz.de/server/rdf/resource/123456789/29"/> <dcterms:abstract xml:lang="eng">The present status and accuracy of determining the electron momentum density from experimental Compton profiles is reviewed. The new spectrometers operating at third-generation synchrotron radiation sources have made possible measurements with 0.1% statistical accuracy at the Compton peak. A comparable accuracy of the Compton profiles is achieved only after careful corrections for departures from the impulse approximation, effects of multiple scattering, and variations in the analyser response function. Detailed descriptions are given of the correction procedures applied to the data collected by the Johann-type scanning spectrometer that is one of the Compton spectrometers in use at the ESRF. Special attention is paid to the calculation and correction of the glitches that are caused by extra reflections of the analyser crystal. The Fourier transform of the Compton profile, the reciprocal form factor, is calculated, and its use in data treatment and presentation is discussed.</dcterms:abstract> <dc:contributor>Boldrini, Barbara</dc:contributor> <dc:creator>Boldrini, Barbara</dc:creator> <dc:contributor>Suortti, Pekka</dc:contributor> <dc:contributor>Huotari, Simo</dc:contributor> <void:sparqlEndpoint rdf:resource="http://localhost/fuseki/dspace/sparql"/> <dc:creator>Suortti, Pekka</dc:creator> <bibo:uri rdf:resource="https://kops.uni-konstanz.de/handle/123456789/58211"/> <dcterms:title>Directional lithium hydride Compton profiles of 0.1% statistical accuracy</dcterms:title> <dcterms:issued>2009-09</dcterms:issued> <dc:creator>Huotari, Simo</dc:creator> </rdf:Description> </rdf:RDF>