Pulse wave analysis with diffusing-wave spectroscopy
Dateien
Datum
Autor:innen
Herausgeber:innen
ISSN der Zeitschrift
Electronic ISSN
ISBN
Bibliografische Daten
Verlag
Schriftenreihe
Auflagebezeichnung
URI (zitierfähiger Link)
DOI (zitierfähiger Link)
Internationale Patentnummer
Link zur Lizenz
EU-Projektnummer
DFG-Projektnummer
Forschungsförderung
Projekt
Open Access-Veröffentlichung
Sammlungen
Titel in einer weiteren Sprache
Publikationstyp
Publikationsstatus
Erschienen in
Zusammenfassung
Hypertension is a major risk factor for cardiovascular disease and thus at the origin of many deaths by e.g. heart attack or stroke. Hypertension is caused by many factors including an increase in arterial sti ff ness which leads to changes in pulse wave velocity and wave reflections. Those often result in an increased left ventricular load which may result in heart failure as well as an increased pulsatile pressure in the microcirculation leading to damage to blood vessels. In order to specifically treat the di ff erent causes of hypertension it is desirable to perform a pulse wave analysis as a complement to measurements of systolic and diastolic pressure by brachial cu ff sphygmomanometry. Here we show that Di ff using Wave Spectroscopy, a novel non-invasive portable tool, is able to monitor blood flow changes with a high temporal resolution. The measured pulse travel times give detailed information of the pulse wave blood flow profile.
Zusammenfassung in einer weiteren Sprache
Fachgebiet (DDC)
Schlagwörter
Konferenz
Rezension
Zitieren
ISO 690
BELAU, Markus, Wolfgang SCHEFFER, Georg MARET, 2017. Pulse wave analysis with diffusing-wave spectroscopy. In: Biomedical Optics Express. 2017, 8(7), pp. 3493-3500. eISSN 2156-7085. Available under: doi: 10.1364/BOE.8.003493BibTex
@article{Belau2017-07-01Pulse-39601, year={2017}, doi={10.1364/BOE.8.003493}, title={Pulse wave analysis with diffusing-wave spectroscopy}, number={7}, volume={8}, journal={Biomedical Optics Express}, pages={3493--3500}, author={Belau, Markus and Scheffer, Wolfgang and Maret, Georg} }
RDF
<rdf:RDF xmlns:dcterms="http://purl.org/dc/terms/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:bibo="http://purl.org/ontology/bibo/" xmlns:dspace="http://digital-repositories.org/ontologies/dspace/0.1.0#" xmlns:foaf="http://xmlns.com/foaf/0.1/" xmlns:void="http://rdfs.org/ns/void#" xmlns:xsd="http://www.w3.org/2001/XMLSchema#" > <rdf:Description rdf:about="https://kops.uni-konstanz.de/server/rdf/resource/123456789/39601"> <foaf:homepage rdf:resource="http://localhost:8080/"/> <bibo:uri rdf:resource="https://kops.uni-konstanz.de/handle/123456789/39601"/> <dc:creator>Maret, Georg</dc:creator> <dcterms:title>Pulse wave analysis with diffusing-wave spectroscopy</dcterms:title> <dcterms:available rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2017-07-18T13:25:00Z</dcterms:available> <dc:creator>Belau, Markus</dc:creator> <dc:contributor>Scheffer, Wolfgang</dc:contributor> <dc:language>eng</dc:language> <dc:date rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2017-07-18T13:25:00Z</dc:date> <dcterms:isPartOf rdf:resource="https://kops.uni-konstanz.de/server/rdf/resource/123456789/41"/> <dcterms:abstract xml:lang="eng">Hypertension is a major risk factor for cardiovascular disease and thus at the origin of many deaths by e.g. heart attack or stroke. Hypertension is caused by many factors including an increase in arterial sti ff ness which leads to changes in pulse wave velocity and wave reflections. Those often result in an increased left ventricular load which may result in heart failure as well as an increased pulsatile pressure in the microcirculation leading to damage to blood vessels. In order to specifically treat the di ff erent causes of hypertension it is desirable to perform a pulse wave analysis as a complement to measurements of systolic and diastolic pressure by brachial cu ff sphygmomanometry. Here we show that Di ff using Wave Spectroscopy, a novel non-invasive portable tool, is able to monitor blood flow changes with a high temporal resolution. The measured pulse travel times give detailed information of the pulse wave blood flow profile.</dcterms:abstract> <dc:contributor>Maret, Georg</dc:contributor> <dcterms:rights rdf:resource="https://rightsstatements.org/page/InC/1.0/"/> <dc:contributor>Belau, Markus</dc:contributor> <void:sparqlEndpoint rdf:resource="http://localhost/fuseki/dspace/sparql"/> <dspace:isPartOfCollection rdf:resource="https://kops.uni-konstanz.de/server/rdf/resource/123456789/41"/> <dcterms:issued>2017-07-01</dcterms:issued> <dc:creator>Scheffer, Wolfgang</dc:creator> <dc:rights>terms-of-use</dc:rights> <dcterms:hasPart rdf:resource="https://kops.uni-konstanz.de/bitstream/123456789/39601/3/Belau_0-414507.pdf"/> <dspace:hasBitstream rdf:resource="https://kops.uni-konstanz.de/bitstream/123456789/39601/3/Belau_0-414507.pdf"/> </rdf:Description> </rdf:RDF>