Publikation:

Consistent characterization of semiconductor saturable absorber mirrors with singe-pulse and pump-probe spectroscopy

Lade...
Vorschaubild

Dateien

fleischhaker_224413.pdf
fleischhaker_224413.pdfGröße: 855.48 KBDownloads: 536

Datum

2013

Herausgeber:innen

Kontakt

ISSN der Zeitschrift

Electronic ISSN

ISBN

Bibliografische Daten

Verlag

Schriftenreihe

Auflagebezeichnung

ArXiv-ID

Internationale Patentnummer

Angaben zur Forschungsförderung

Projekt

Open Access-Veröffentlichung
Open Access Green
Core Facility der Universität Konstanz

Gesperrt bis

Titel in einer weiteren Sprache

Publikationstyp
Zeitschriftenartikel
Publikationsstatus
Published

Erschienen in

Optics Express. 2013, 21(6), pp. 6764-6776. eISSN 1094-4087. Available under: doi: 10.1364/OE.21.006764

Zusammenfassung

We study the comparability of the two most important measurement methods used for the characterization of semiconductor saturable absorber mirrors (SESAMs). For both methods, single-pulse spectroscopy (SPS) and pump-probe spectroscopy (PPS), we analyze in detail the time-dependent saturation dynamics inside a SESAM. Based on this analysis, we find that fluence-dependent PPS at complete spatial overlap and zero time delay is equivalent to SPS. We confirm our findings experimentally by comparing data from SPS and PPS of two samples. We show how to interpret this data consistently and we give explanations for possible deviations.

Zusammenfassung in einer weiteren Sprache

Fachgebiet (DDC)
530 Physik

Schlagwörter

Mode-locked lasers, nonlinear optical devices, reflection

Konferenz

Rezension
undefined / . - undefined, undefined

Forschungsvorhaben

Organisationseinheiten

Zeitschriftenheft

Zugehörige Datensätze in KOPS

Zitieren

ISO 690FLEISCHHAKER, Robert, Nico KRAUSS, Farina SCHÄTTIGER, Thomas DEKORSY, 2013. Consistent characterization of semiconductor saturable absorber mirrors with singe-pulse and pump-probe spectroscopy. In: Optics Express. 2013, 21(6), pp. 6764-6776. eISSN 1094-4087. Available under: doi: 10.1364/OE.21.006764
BibTex
@article{Fleischhaker2013-03-25Consi-22441,
  year={2013},
  doi={10.1364/OE.21.006764},
  title={Consistent characterization of semiconductor saturable absorber mirrors with singe-pulse and pump-probe spectroscopy},
  number={6},
  volume={21},
  journal={Optics Express},
  pages={6764--6776},
  author={Fleischhaker, Robert and Krauß, Nico and Schättiger, Farina and Dekorsy, Thomas}
}
RDF
<rdf:RDF
    xmlns:dcterms="http://purl.org/dc/terms/"
    xmlns:dc="http://purl.org/dc/elements/1.1/"
    xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#"
    xmlns:bibo="http://purl.org/ontology/bibo/"
    xmlns:dspace="http://digital-repositories.org/ontologies/dspace/0.1.0#"
    xmlns:foaf="http://xmlns.com/foaf/0.1/"
    xmlns:void="http://rdfs.org/ns/void#"
    xmlns:xsd="http://www.w3.org/2001/XMLSchema#" > 
  <rdf:Description rdf:about="https://kops.uni-konstanz.de/server/rdf/resource/123456789/22441">
    <dc:date rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2013-03-15T09:01:43Z</dc:date>
    <dc:contributor>Fleischhaker, Robert</dc:contributor>
    <void:sparqlEndpoint rdf:resource="http://localhost/fuseki/dspace/sparql"/>
    <dcterms:bibliographicCitation>Optics Express ; 21 (2013), 6. - S. 6764-6776</dcterms:bibliographicCitation>
    <dcterms:abstract xml:lang="eng">We study the comparability of the two most important measurement methods used for the characterization of semiconductor saturable absorber mirrors (SESAMs). For both methods, single-pulse spectroscopy (SPS) and pump-probe spectroscopy (PPS), we analyze in detail the time-dependent saturation dynamics inside a SESAM. Based on this analysis, we find that fluence-dependent PPS at complete spatial overlap and zero time delay is equivalent to SPS. We confirm our findings experimentally by comparing data from SPS and PPS of two samples. We show how to interpret this data consistently and we give explanations for possible deviations.</dcterms:abstract>
    <dcterms:isPartOf rdf:resource="https://kops.uni-konstanz.de/server/rdf/resource/123456789/41"/>
    <dcterms:hasPart rdf:resource="https://kops.uni-konstanz.de/bitstream/123456789/22441/1/fleischhaker_224413.pdf"/>
    <dc:creator>Dekorsy, Thomas</dc:creator>
    <dc:contributor>Dekorsy, Thomas</dc:contributor>
    <dcterms:rights rdf:resource="https://rightsstatements.org/page/InC/1.0/"/>
    <bibo:uri rdf:resource="http://kops.uni-konstanz.de/handle/123456789/22441"/>
    <dc:creator>Fleischhaker, Robert</dc:creator>
    <dc:contributor>Schättiger, Farina</dc:contributor>
    <dcterms:title>Consistent characterization of semiconductor saturable absorber mirrors with singe-pulse and pump-probe spectroscopy</dcterms:title>
    <dc:contributor>Krauß, Nico</dc:contributor>
    <dc:creator>Krauß, Nico</dc:creator>
    <dcterms:issued>2013-03-25</dcterms:issued>
    <foaf:homepage rdf:resource="http://localhost:8080/"/>
    <dspace:isPartOfCollection rdf:resource="https://kops.uni-konstanz.de/server/rdf/resource/123456789/41"/>
    <dc:rights>terms-of-use</dc:rights>
    <dspace:hasBitstream rdf:resource="https://kops.uni-konstanz.de/bitstream/123456789/22441/1/fleischhaker_224413.pdf"/>
    <dc:creator>Schättiger, Farina</dc:creator>
    <dcterms:available rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2013-03-15T09:01:43Z</dcterms:available>
    <dc:language>eng</dc:language>
  </rdf:Description>
</rdf:RDF>

Interner Vermerk

xmlui.Submission.submit.DescribeStep.inputForms.label.kops_note_fromSubmitter

Kontakt
URL der Originalveröffentl.

Prüfdatum der URL

Prüfungsdatum der Dissertation

Finanzierungsart

Kommentar zur Publikation

Allianzlizenz
Corresponding Authors der Uni Konstanz vorhanden
Internationale Co-Autor:innen
Universitätsbibliographie
Ja
Begutachtet
Diese Publikation teilen