Publikation: A variable-stiffness shoe lowers the knee adduction moment in subjects with symptoms of medial compartment knee osteoarthritis
Dateien
Datum
Autor:innen
Herausgeber:innen
ISSN der Zeitschrift
Electronic ISSN
ISBN
Bibliografische Daten
Verlag
Schriftenreihe
Auflagebezeichnung
URI (zitierfähiger Link)
DOI (zitierfähiger Link)
Internationale Patentnummer
Angaben zur Forschungsförderung
Projekt
Open Access-Veröffentlichung
Sammlungen
Core Facility der Universität Konstanz
Titel in einer weiteren Sprache
Publikationstyp
Publikationsstatus
Erschienen in
Zusammenfassung
The purpose of this study was to evaluate the effectiveness of variable-stiffness shoes in lowering the peak external knee adduction moment during walking in subjects with symptomatic medial compartment knee osteoarthritis. The influence on other lower extremity joints was also investigated. The following hypotheses were tested: (1) variable-stiffness shoes will lower the knee adduction moment in the symptomatic knee compared to control shoes; (2) reductions in knee adduction moment will be greater at faster speeds; (3) subjects with higher initial knee adduction moments in control shoes will have greater reductions in knee adduction moment with the intervention shoes; and (4) variable-stiffness shoes will cause secondary changes in the hip and ankle frontal plane moments. Seventy-nine individuals were tested at self-selected slow, normal, and fast speeds with a constant-stiffness control shoe and a variable-stiffness intervention shoe. Peak moments for each condition were assessed using a motion capture system and force plate. The intervention shoes reduced the peak knee adduction moment compared to control at all walking speeds, and reductions increased with increasing walking speed. The magnitude of the knee adduction moment prior to intervention explained only 11.9% of the variance in the absolute change in maximum knee adduction moment. Secondary changes in frontal plane moments showed primarily reductions in other lower extremity joints. This study showed that the variable-stiffness shoe reduced the knee adduction moment in subjects with medial compartment knee osteoarthritis without the discomfort of a fixed wedge or overloading other joints, and thus can potentially slow the progression of knee osteoarthritis.
Zusammenfassung in einer weiteren Sprache
Fachgebiet (DDC)
Schlagwörter
Konferenz
Rezension
Zitieren
ISO 690
ERHART, Jennifer C., Annegret MÜNDERMANN, Barbara ELSPAS, Nick J. GIORI, Thomas P. ANDRIACCHI, 2008. A variable-stiffness shoe lowers the knee adduction moment in subjects with symptoms of medial compartment knee osteoarthritis. In: Journal of Biomechanics. 2008, 41(12), pp. 2720-2725. ISSN 0021-9290. Available under: doi: 10.1016/j.jbiomech.2008.06.016BibTex
@article{Erhart2008-08-28varia-17886, year={2008}, doi={10.1016/j.jbiomech.2008.06.016}, title={A variable-stiffness shoe lowers the knee adduction moment in subjects with symptoms of medial compartment knee osteoarthritis}, number={12}, volume={41}, issn={0021-9290}, journal={Journal of Biomechanics}, pages={2720--2725}, author={Erhart, Jennifer C. and Mündermann, Annegret and Elspas, Barbara and Giori, Nick J. and Andriacchi, Thomas P.} }
RDF
<rdf:RDF xmlns:dcterms="http://purl.org/dc/terms/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:bibo="http://purl.org/ontology/bibo/" xmlns:dspace="http://digital-repositories.org/ontologies/dspace/0.1.0#" xmlns:foaf="http://xmlns.com/foaf/0.1/" xmlns:void="http://rdfs.org/ns/void#" xmlns:xsd="http://www.w3.org/2001/XMLSchema#" > <rdf:Description rdf:about="https://kops.uni-konstanz.de/server/rdf/resource/123456789/17886"> <dcterms:available rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2012-02-06T08:03:02Z</dcterms:available> <void:sparqlEndpoint rdf:resource="http://localhost/fuseki/dspace/sparql"/> <dc:contributor>Mündermann, Annegret</dc:contributor> <dc:contributor>Andriacchi, Thomas P.</dc:contributor> <dc:creator>Erhart, Jennifer C.</dc:creator> <dcterms:issued>2008-08-28</dcterms:issued> <dc:creator>Mündermann, Annegret</dc:creator> <dc:contributor>Giori, Nick J.</dc:contributor> <foaf:homepage rdf:resource="http://localhost:8080/"/> <dspace:isPartOfCollection rdf:resource="https://kops.uni-konstanz.de/server/rdf/resource/123456789/35"/> <dc:language>eng</dc:language> <dc:rights>terms-of-use</dc:rights> <dc:contributor>Elspas, Barbara</dc:contributor> <bibo:uri rdf:resource="http://kops.uni-konstanz.de/handle/123456789/17886"/> <dcterms:isPartOf rdf:resource="https://kops.uni-konstanz.de/server/rdf/resource/123456789/35"/> <dc:date rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2012-02-06T08:03:02Z</dc:date> <dcterms:abstract xml:lang="eng">The purpose of this study was to evaluate the effectiveness of variable-stiffness shoes in lowering the peak external knee adduction moment during walking in subjects with symptomatic medial compartment knee osteoarthritis. The influence on other lower extremity joints was also investigated. The following hypotheses were tested: (1) variable-stiffness shoes will lower the knee adduction moment in the symptomatic knee compared to control shoes; (2) reductions in knee adduction moment will be greater at faster speeds; (3) subjects with higher initial knee adduction moments in control shoes will have greater reductions in knee adduction moment with the intervention shoes; and (4) variable-stiffness shoes will cause secondary changes in the hip and ankle frontal plane moments. Seventy-nine individuals were tested at self-selected slow, normal, and fast speeds with a constant-stiffness control shoe and a variable-stiffness intervention shoe. Peak moments for each condition were assessed using a motion capture system and force plate. The intervention shoes reduced the peak knee adduction moment compared to control at all walking speeds, and reductions increased with increasing walking speed. The magnitude of the knee adduction moment prior to intervention explained only 11.9% of the variance in the absolute change in maximum knee adduction moment. Secondary changes in frontal plane moments showed primarily reductions in other lower extremity joints. This study showed that the variable-stiffness shoe reduced the knee adduction moment in subjects with medial compartment knee osteoarthritis without the discomfort of a fixed wedge or overloading other joints, and thus can potentially slow the progression of knee osteoarthritis.</dcterms:abstract> <dc:creator>Andriacchi, Thomas P.</dc:creator> <dcterms:rights rdf:resource="https://rightsstatements.org/page/InC/1.0/"/> <dcterms:bibliographicCitation>Publ. in: Journal of Biomechanics ; 41(2008), 12. - S. 2720-2725</dcterms:bibliographicCitation> <dc:creator>Elspas, Barbara</dc:creator> <dc:creator>Giori, Nick J.</dc:creator> <dc:contributor>Erhart, Jennifer C.</dc:contributor> <dcterms:title>A variable-stiffness shoe lowers the knee adduction moment in subjects with symptoms of medial compartment knee osteoarthritis</dcterms:title> </rdf:Description> </rdf:RDF>